Skip to content

SMD code KZ in SOD-123

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 32 parts are ranked, with a meter test that settles it. It works on a dead part too.

15 parts have no package on record. Nothing rules them out, so they stay.

  • IXD5120C292NR-GVoltage supervisor, IXYSVoltage supervisorIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 2.9V±2% -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5127C54CNRVoltage supervisor, IXYSVoltage supervisorIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, -Reset PPO, -MR, 200ms Rt delay
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5127N54HNRVoltage supervisor, IXYSVoltage supervisorIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, +Reset ODO, -MR, 200ms Rt delay
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • MDZ5245CZener diode, FutureWafer TechZener diodeFutureWafer Tech
    What it is
    Zener diode
    Maker
    FutureWafer Tech
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode: 14.25..15.75V, Zzt=16.0, Izt=2.0mA, 150mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • P6SMAJ11ADFQTVS diode, Diodes IncorporatedTVS diodeDiodes Incorporated
    What it is
    TVS diode
    Maker
    Diodes Incorporated
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Transient voltage supressor: Vrwm=11V, Vbr=12.20..14.40V, Ipp=33.0A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • R5426D116DANisshinbo Micro DevicesNot recordedNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Li-Ion Battery Over-charge/discharge Protection, Vc/d=1,16V
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SMBS11ATVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
    What it is
    TVS diode
    Maker
    Formosa Microsemi
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Transient voltage supressor: Vrwm=11V, Vbr=12.2..13.5V, Ipp=33.0A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • UNR32ATDigital transistor (NPN, resistors built in), PanasonicDigital transistor (NPN, resistors built in)Panasonic
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    Panasonic
    Package
    Not recorded
    Pins
    Not recorded
    Details
    NPN transistor: Sw, 50V, 80mA, 100mW, 150MHz, R1/R2=22k/47k
    Source
    Published code list

    Is it dead? The meter test is below: Digital transistor.

  • XC6109N09ANVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 0,9V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6119N19ANRVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 1.9V±2%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6120C29NVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 2.9V±2%, CMOS +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6127C54CNRVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, -Reset PPO, -MR, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6127N54HNRVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, +Reset ODO, -MR, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6129C54F9R-GVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, -Reset PPO, Rel. Delay, Det. Delay, Undef. Protect
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6129C54FNR-GVoltage supervisor, TorexVoltage supervisorTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 5.4V±0.8%, -Reset PPO, Rel. Delay, Det. Delay, Undef. Protect
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.