Skip to content

SMD code L1-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

87 parts are printed L1-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ABAT54M-HFSOT-723Schottky diode, 3 pins, ComchipSchottky diodeSOT-7233 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOT-723
    Pins
    3
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT42WSSOD-323Schottky diode, 2 pins, VishaySchottky diodeSOD-3232 pinsVishay
    What it is
    Schottky diode
    Maker
    Vishay
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT54M-HFSOT-723Schottky diode, 3 pins, ComchipSchottky diodeSOT-7233 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOT-723
    Pins
    3
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT54TSOT-416Schottky diode, 3 pins, onsemiSchottky diodeSOT-4163 pinsonsemi
    What it is
    Schottky diode
    Maker
    onsemi
    Package
    SOT-416
    Pins
    3
    Details
    Single Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT54T-CSOT-523Schottky diode, 3 pins, SeCoSSchottky diodeSOT-5233 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOT-523
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT54T-HFSOT-523Schottky diode, 3 pins, ComchipSchottky diodeSOT-5233 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOT-523
    Pins
    3
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BAT54TCR-CSOT-523Schottky diode, 3 pins, SeCoSSchottky diodeSOT-5233 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOT-523
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BZD17C68PSOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZD27C27PSOD-123FTVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSOD-123F2 pinsGalaxy Microelectronics
    What it is
    TVS diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123F
    Pins
    2
    Details
    22V, 150W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • BZX384-B5V6SOD-323Zener diode, 2 pins, NexperiaZener diodeSOD-3232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CDBR3-54M-HFSOT-723Schottky diode, 3 pins, ComchipSchottky diodeSOT-7233 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOT-723
    Pins
    3
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • GSBAT54TSOT-523Schottky diode, 3 pins, Good-ArkSchottky diodeSOT-5233 pinsGood-Ark
    What it is
    Schottky diode
    Maker
    Good-Ark
    Package
    SOT-523
    Pins
    3
    Details
    Schottky diode, 30 V, 200 mA
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 3 more parts have no package on record
    • BB202LXVaricap diode, 2 pins, NXPVaricap diodeNot recorded2 pinsNXP
      What it is
      Varicap diode
      Maker
      NXP
      Package
      Not recorded
      Pins
      2
      Details
      Low-voltage variable capacitance diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: PIN diode or varicap.

    • BFCN-5200+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter, 4250-6300 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • ESDALC6V1-1U2ESD protection diode, STMicroelectronicsESD protection diodeNot recordedNot recordedSTMicroelectronics
      What it is
      ESD protection diode
      Maker
      STMicroelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as L1-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 33 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.