Skip to content

SMD code LJt

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, t, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and LJ was searched.

48 parts are printed LJt

Not sure which one you have?

Answer up to 4 quick questions and these 48 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • S-8053ALR-LJSOT-893 pins, ABLICNot recordedSOT-893 pinsABLIC
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-89
    Pins
    3
    Details
    equivalent S-8053ALR
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • SDM10U45LPSOD-8822 pins, Diodes IncorporatedNot recordedSOD-8822 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOD-882
    Pins
    2
    Details
    Si-diode: Schottky, 45V, 100mA, Vf<800mV(100mA)
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • SK415CSMCSchottky diode, 2 pins, Fagor ElectronicaSchottky diodeSMC2 pinsFagor Electronica
    What it is
    Schottky diode
    Maker
    Fagor Electronica
    Package
    SMC
    Pins
    2
    Details
    Diode: SBR, 150V, 4A, Vf<0.9V(4A)
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.