SMD code M in DFN
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
6 parts in DFN are printed M
Not sure which one you have?
Answer up to 4 quick questions and these 30 parts are ranked, with a meter test that settles it. It works on a dead part too.
MC74VHC1GT14MU2DFNLogic gate, onsemiLogic gateNot recordedonsemi
- What it is
- Logic gate
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- Single Schmitt-Trigger Inverter
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
MC74VHC1GT14MU3DFNLogic gate, onsemiLogic gateNot recordedonsemi
- What it is
- Logic gate
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- Single Schmitt-Trigger Inverter
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
7SB384MUTCGDFN6 pins, onsemiNot recorded6 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- 6
- Source
- Published code list
Is it dead? The meter test is below: This part.
FP6121-LWDGDFNLDO regulator, FitipowerLDO regulatorNot recordedFitipower
- What it is
- LDO regulator
- Maker
- Fitipower
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, Dual out, Vout1/Vout2=1.8V/2.6V±2%, 150mA, +CE, Green pack.
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FP6146-28WDGDFNLDO regulator, FitipowerLDO regulatorNot recordedFitipower
- What it is
- LDO regulator
- Maker
- Fitipower
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.8V±2%, 300mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
NLU1GT14MUDFNonsemiNot recordedNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- CMOS logic IC: Inverter with Schmitt-trigger input, TTL level
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
9 more parts have no package on record. Nothing rules them out, so they stay.
AOZ8331DI-04ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
AOZ8660BLS-01ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BGS8L2RF switch, 6 pins, NXPRF switch6 pinsNXP
- What it is
- RF switch
- Maker
- NXP
- Package
- Not recorded
- Pins
- 6
- Details
- 1 General description 2 Features and benefits
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
CPDWZ3V3MSBP-HFESD protection diode, ComchipESD protection diodeNot recordedComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 3.3 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ES45DPKTVS diode, ETEKTVS diodeNot recordedETEK
- What it is
- TVS diode
- Maker
- ETEK
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ES45DPXTVS diode, ETEKTVS diodeNot recordedETEK
- What it is
- TVS diode
- Maker
- ETEK
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LESD11LV12CT5GESD protection diode, LRCESD protection diodeNot recordedLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 10 V, IR @VRWM 1 μA, VBR Min 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PESD12ULCESD protection diode, ProTek DevicesESD protection diodeNot recordedProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Low Capacitance TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PHS524CESD protection diode, ProTek DevicesESD protection diodeNot recordedProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- High Powered Surge Protection TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with M
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 2,293 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.