Skip to content

SMD code M0 in US8

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 16 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • NL27WZ125USGUS8Logic gate, 8 pins, onsemiLogic gate8 pinsonsemi
    What it is
    Logic gate
    Maker
    onsemi
    Package
    US8
    Pins
    8
    Details
    Dual Buffer with 3 State Outputs
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • NL27WZ125USG-QUS8Logic gate, 8 pins, onsemiLogic gate8 pinsonsemi
    What it is
    Logic gate
    Maker
    onsemi
    Package
    US8
    Pins
    8
    Details
    Dual Buffer with 3 State Outputs
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • NL27WZ125USUS88 pins, onsemiNot recorded8 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    US8
    Pins
    8
    Details
    CMOS logic IC: Dual bus buffer with 3-state output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 12 more parts have no package on record. Nothing rules them out, so they stay.
    • NL17SZ125DBVLogic gate, onsemiLogic gateNot recordedonsemi
      What it is
      Logic gate
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Non Inverting 3 State Buffer
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-40GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-40GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-40PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-40PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EC95808N40C7IVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EC95808N40C7SVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5120N302NR-GVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.0V±2% -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • R1100D101CNisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: U-low Icc, 1V±2%, 180mA
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • R1131D101BNisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, -CE, 1V±2%, 300mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • XC6GN2002HRTorexNot recordedNot recordedTorex
      What it is
      Not recorded
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,0V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6225A17ANR-GLDO regulator, TorexLDO regulatorNot recordedTorex
      What it is
      LDO regulator
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 1.75V±2%, 30mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as M0

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with M0

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 194 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.