Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
6 parts in SOT-23 are printed M33
Not sure which one you have?
Answer up to 4 quick questions and these 7 parts are ranked, with a meter test that settles it. It works on a dead part too.
BF861ASOT-23JFET, PhiJFETPhi
- What it is
- JFET
- Maker
- Phi
- Package
- SOT-23
- Pins
- 3
- Details
- N-channel junction FETs
- Source
- Published code list
Is it dead? The meter test is below: JFET.
FN1A4MSOT-23NEC ElectronicsNot recordedNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-23
- Pins
- 3
- Details
- Si-pnp-Digi: Sw, 60V, 100mA, 200mW, R1/R2=10k/10k
- Source
- Published code list
Is it dead? The meter test is below: This part.
HE61CN2302MRSOT-23Voltage supervisor, Heermicr SemicconductorVoltage supervisorHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.3V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HE7023MNNRSOT-23Voltage supervisor, Heermicr SemicconductorVoltage supervisorHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.3V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC61CN2302MSOT-23TorexNot recordedTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 2,3V, Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XE61CN2345MRSOT-23Voltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.3V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
1 more part has no package on record. Nothing rules it out, so it stays.
XC61GN2302HRVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.3V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
JFET
Ohms range for drain to source, diode range for the gate, part lifted.
Working, it reads
Drain to source conducts both ways at a few hundred ohms, depending on the part, and some meters beep on it. The gate reads one junction to drain and to source, about 0.6 to 0.7 V, and open the other way.
Dead, it reads
- The gate the same both ways to drain or source, near 0 V with a continuous beep: gate shorted.
- Drain to source open: the channel has failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- Drain to source resistance varies from part to part. An identical part elsewhere on the board shows what is normal.
- Watch for:
- A good channel can beep like a short between drain and source. That is normal; the gate junction says whether it has failed.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with M33
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.