Skip to content

SMD code M4A

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

19 parts are printed M4A

Not sure which one you have?

Answer up to 4 quick questions and these 19 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • MMBT4401SOT-23NPN transistor, 3 pins, PanjitNPN transistorSOT-233 pinsPanjit
    What it is
    NPN transistor
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    NPN bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • MMBT4401-AUSOT-23Transistor, 3 pins, PanjitTransistorSOT-233 pinsPanjit
    What it is
    Transistor
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • MMBT4401WSOT-323NPN transistor, 3 pins, PanjitNPN transistorSOT-3233 pinsPanjit
    What it is
    NPN transistor
    Maker
    Panjit
    Package
    SOT-323
    Pins
    3
    Details
    NPN bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • MMDT4401SOT-363NPN transistor, 6 pins, PanjitNPN transistorSOT-3636 pinsPanjit
    What it is
    NPN transistor
    Maker
    Panjit
    Package
    SOT-363
    Pins
    6
    Details
    NPN bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • ADM6711TAKSZSOT-343Voltage supervisor, 4 pins, Analog DevicesVoltage supervisorSOT-3434 pinsAnalog Devices
    What it is
    Voltage supervisor
    Maker
    Analog Devices
    Package
    SOT-343
    Pins
    4
    Details
    Voltage detector IC: 3.08V±1%, -Reset PPO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5108N24AMRSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 2.4V±2%, Hst, -Reset ODO, Cd
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5118C14AMR-GSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 1.4V±30mV, ±Reset PPO, Sense, Hst 5%, Cd
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • MBV109T1SOT-3233 pins, onsemiNot recordedSOT-3233 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-323
    Pins
    3
    Details
    equivalent MV209
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • MMBV109SOT-3233 pins, onsemiNot recordedSOT-3233 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-323
    Pins
    3
    Details
    MV209 varicap
    Source
    Published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • MMBV109LT1SOT-233 pins, onsemiNot recordedSOT-233 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • TC105403ECTSOT-23-5DC-DC converter, 5 pins, MicrochipDC-DC converterSOT-23-55 pinsMicrochip
    What it is
    DC-DC converter
    Maker
    Microchip
    Package
    SOT-23-5
    Pins
    5
    Details
    DC/DC voltage converter IC: PWM/PFM st-dwn, 300kHz, 4.0V±1%, 1A, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC6108N24AMRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS-IC: Voltage Detector 2,4V, 5%, Hst, -Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 3 more parts have no package on record
    • IXD5108N24AGRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.4V±2%, Hst., -Reset ODO, Cd
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5118C14AGR-GVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.4V±30mV, ±Reset PPO, Sense, Hst. 5%, Cd
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6108N24AGRVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,4V5%, Hst, -Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.