SMD code N9 in DFN
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
3 parts in DFN are printed N9
Not sure which one you have?
Answer up to 4 quick questions and these 40 parts are ranked, with a meter test that settles it. It works on a dead part too.
ISL9016IRUFCZDFNLDO regulator, IntersilLDO regulatorIntersil
- What it is
- LDO regulator
- Maker
- Intersil
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, Dual out, Vo1/Vo2=2.5V/1.8V±1.8%, 150mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
R3117K363ADFNVoltage supervisor, RicohVoltage supervisorRicoh
- What it is
- Voltage supervisor
- Maker
- Ricoh
- Package
- DFN
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.6V±1%, -Reset ODO, Sense
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
RP114K121B5DFNLDO regulator, RicohLDO regulatorRicoh
- What it is
- LDO regulator
- Maker
- Ricoh
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 1.25V±1%, 300mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
12 more parts have no package on record. Nothing rules them out, so they stay.
KRC422VDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KST05UL5E-CESD protection diode, SeCoSESD protection diodeSeCoS
- What it is
- ESD protection diode
- Maker
- SeCoS
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LDAN222T1GSwitching diode, LRCSwitching diodeLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Switching diode, VR 80 V, IF 100 mA, VF Max 1.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
NC7SZ74L8Voltage supervisor, onsemiVoltage supervisoronsemi
- What it is
- Voltage supervisor
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TinyLogic UHS D-Type, Flip-Flop with Preset and Clear
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
S-LDAN222T1GSwitching diode, LRCSwitching diodeLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Switching diode, VR 80 V, IF 100 mA, VF Max 1.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
AP8821N-59GIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.9V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-59GSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.9V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-59PIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.9V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-59PSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.9V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BCT2562ELS09-TRLDO regulator, Broadchip Technology GroupLDO regulatorBroadchip Technology Group
- What it is
- LDO regulator
- Maker
- Broadchip Technology Group
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 0.9V±2%, 600mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
BD46E411G-MVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.1V±1%, -MR, -Reset PPO, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BL8064CB3ATR19LDO regulator, Shanghai BellingLDO regulatorShanghai Belling
- What it is
- LDO regulator
- Maker
- Shanghai Belling
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 1.9V±2%, 250mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with N9
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 14 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.