Skip to content

SMD code N91

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

N91 on a chip capacitor

910 pF

910 pF capacitor

The n is both the decimal point and the unit: 910 pF.

Check it with a meter

Lift one end and measure it on a capacitance range. A good one reads close to 910 pF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 910 pF.

On a transistor or diode body (SOT-23, SOT-343, SOT-23-5), N91 is a part code instead. Those parts are listed below.

5 parts are printed N91

Not sure which one you have?

Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • HE61CN3901MRSOT-233 pins, Heermicr SemicconductorSOT-233 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.9V±1%, +Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HE7039MNM5R1SOT-23-55 pins, Heermicr SemicconductorSOT-23-55 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 3.9V±1%, +Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HE7039MNNR1SOT-233 pins, Heermicr SemicconductorSOT-233 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.9V±1%, +Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HE7039MNPR1SOT-893 pins, Heermicr SemicconductorSOT-893 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-89
    Pins
    3
    Details
    Voltage detector IC: 3.9V±1%, +Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SO642SOT-233 pins, SGS-Thomson MicroelectronicsSOT-233 pinsSGS-Thomson Microelectronics
    What it is
    Not recorded
    Maker
    SGS-Thomson Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    npn Vce 300V
    Source
    Published code list

    Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as N91

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.