Skip to content

SMD code NDp

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and ND was searched.

98 parts are printed NDp

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZT52C8V2SOD-123Zener diode, 2 pins, DiotecZener diodeSOD-1232 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOD-123
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZT52C8V2WSOD-123Zener diode, 2 pins, JinYu semiconductorZener diodeSOD-1232 pinsJinYu semiconductor
    What it is
    Zener diode
    Maker
    JinYu semiconductor
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode: 7.79..8.61V, Izt=5mA, Zzt=15, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX84C3V3CCWSOT-323Zener diode, 3 pins, JinYu semiconductorZener diodeSOT-3233 pinsJinYu semiconductor
    What it is
    Zener diode
    Maker
    JinYu semiconductor
    Package
    SOT-323
    Pins
    3
    Details
    Zener diode: Dual, 3.1..3.5V, Zzt=95, Izt=5mA, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • EC76SMBJ54SMBTVS diode, 2 pins, E-CMOSTVS diodeSMB2 pinsE-CMOS
    What it is
    TVS diode
    Maker
    E-CMOS
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vbr=60.0..73.3V, Vrwm=54V, Ipp=6.2A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ELM7314CBC2ASOT-353Voltage supervisor, 5 pins, ELM TechnologyVoltage supervisorSOT-3535 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-353
    Pins
    5
    Details
    Voltage detector IC: 1.4V±30mV, -Reset PPO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ELM99433BSOT-89-5LDO regulator, 5 pins, ELM TechnologyLDO regulatorSOT-89-55 pinsELM Technology
    What it is
    LDO regulator
    Maker
    ELM Technology
    Package
    SOT-89-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 4.3V±2%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • EUP7201-2.5/2.8VSOT-23-6LDO regulator, 6 pins, Eutech MicroelectronicsLDO regulatorSOT-23-66 pinsEutech Microelectronics
    What it is
    LDO regulator
    Maker
    Eutech Microelectronics
    Package
    SOT-23-6
    Pins
    6
    Details
    Linear voltage regulator IC: LDO, Dual out, Vout1/Vout2=2.5V/2.8V±2%, 150mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • EUP7201-2.5/2.8VIR1SOT-23-66 pins, EutechNot recordedSOT-23-66 pinsEutech
    What it is
    Not recorded
    Maker
    Eutech
    Package
    SOT-23-6
    Pins
    6
    Details
    Linear Voltage Regulator
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • MIC1815-10USOT-23Voltage supervisor, 3 pins, MicrelVoltage supervisorSOT-233 pinsMicrel
    What it is
    Voltage supervisor
    Maker
    Micrel
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 2.88V±1.5%, -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • MIC1815-10UYSOT-23Voltage supervisor, 3 pins, MicrelVoltage supervisorSOT-233 pinsMicrel
    What it is
    Voltage supervisor
    Maker
    Micrel
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 2.88V±1.5%, -Reset PPO, Pb-Free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 5 more parts have no package on record
    • DRC5114TDigital transistor (NPN, resistors built in), PanasonicDigital transistor (NPN, resistors built in)Not recordedNot recordedPanasonic
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      Panasonic
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Sw, 50V, 100mA, 150mW, R1=10k
      Source
      Published code list

      Is it dead? The meter test is below: Digital transistor.

    • EUP7201-2.5/2.8ULDO regulator, Eutech MicroelectronicsLDO regulatorNot recordedNot recordedEutech Microelectronics
      What it is
      LDO regulator
      Maker
      Eutech Microelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, Dual out, Vout1/Vout2=2.5V/2.8V±2%, 150mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • EUP7201-2.5/2.8UIR1EutechNot recordedNot recordedNot recordedEutech
      What it is
      Not recorded
      Maker
      Eutech
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear Voltage Regulator
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • IXD5127C22DNRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.2V±0.8%, -Reset PPO, -MR, 400ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • KRC824FKECNot recordedNot recordedNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Dual, Sw, 20V, 50mA, 50mW, R1/R2=47k/47k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.