SMD code NM in SOT-89
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
4 parts in SOT-89 are printed NM
Not sure which one you have?
Answer up to 4 quick questions and these 34 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SCR533PSOT-89NPN transistor, ROHMNPN transistorROHM
- What it is
- NPN transistor
- Maker
- ROHM
- Package
- SOT-89
- Pins
- 3
- Details
- Middle Power Transistor (50V / 3A)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
2SCR533P5SOT-89NPN transistor, ROHMNPN transistorROHM
- What it is
- NPN transistor
- Maker
- ROHM
- Package
- SOT-89
- Pins
- 3
- Details
- Middle Power Transistors (50V / 3A)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
2SC2780-MSOT-89NEC ElectronicsNot recordedNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Si-npn: AF-Amp, 140V, 50mA, 2W, 120MHz, B=90..180
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC2780NMSOT-89RenesasNot recordedRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
11 more parts have no package on record. Nothing rules them out, so they stay.
HFCN-440+RF filter, Mini-CircuitsRF filterMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter, 500-2500 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
KRC411EDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRC411VDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRC661EDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRC661UDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRC861EDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRC861UDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
SMF64A-MFHTVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMF64A-MFLTVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMF64A-MSTVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMF64A-MS-Q1TVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with NM
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.