Skip to content

SMD code NN in SOT-353

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 29 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ELM7323CBC2ASOT-353Voltage supervisor, ELM TechnologyVoltage supervisorELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-353
    Pins
    5
    Details
    Voltage detector IC: 2.3V±30mV, -Reset PPO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • BAR65-02LPIN diode, InfineonPIN diodeInfineon
      What it is
      PIN diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: PIN diode or varicap.

    • KRC662EDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Digital transistor.

    • NC7ST08L6Logic gate, onsemiLogic gateonsemi
      What it is
      Logic gate
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      TinyLogic HST 2-Input AND Gate
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • BD49L59GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Detector
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD52E49G-MVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.9V±1%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU46L314GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.1V±1%, -Reset PPO, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EUP7201-3.0/3.0ULDO regulator, Eutech MicroelectronicsLDO regulatorEutech Microelectronics
      What it is
      LDO regulator
      Maker
      Eutech Microelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, Dual out, Vout1/Vout2=3.0V/3.0V±2%, 150mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • EUP7201-3.0/3.0UIR1LDO regulator, EutechLDO regulatorEutech
      What it is
      LDO regulator
      Maker
      Eutech
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Dual ,Low-Noise,150mA LDO Regulator
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • IXD5109N30ANVoltage supervisor, IXYSVoltage supervisorIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.0V±2%, +Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C36DNRVoltage supervisor, IXYSVoltage supervisorIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.6V±0.8%, -Reset PPO, -MR, 400ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • KRC412EDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 100mW, 200MHz, R1=100k
      Source
      Published code list

      Is it dead? The meter test is below: Digital transistor.

    • KRC412VDigital transistor (NPN, resistors built in), KECDigital transistor (NPN, resistors built in)KEC
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 100mW, 200MHz, R1=100k
      Source
      Published code list

      Is it dead? The meter test is below: Digital transistor.

    • KRC662UKECNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Dual, Sw, 50V, 100mA, 200mW, R1=100k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • KRC833FKECNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Dual, Sw, 20V, 50mA, 50mW, R1=22k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with NN

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.