SMD code P2C
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
16 parts are printed P2C
Not sure which one you have?
Answer up to 4 quick questions and these 16 parts are ranked, with a meter test that settles it. It works on a dead part too.
PAM1CANSOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- CAN BUS ESD Protection Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PESD1CANSOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- 24V, 200W, Surface Mount TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PESD1FLEXSOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- FLEX BUS ESD Protection Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
CMPS5063SOT-233 pins, Central SemiconductorNot recordedSOT-233 pinsCentral Semiconductor
- What it is
- Not recorded
- Maker
- Central Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Thyristor controlled rectifier: Vdrm=300V, It=250mA, 350mW, 2.8us
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
IXD5108N42CMRSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 4.2V±2%, Hst, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5118C32CMR-GSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 3.2V±2%, ±Reset PPO, Sense, Hst 5%
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
P0102CLSOT-233 pins, STMicroelectronicsNot recordedSOT-233 pinsSTMicroelectronics
- What it is
- Not recorded
- Maker
- STMicroelectronics
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
P0102CNSOT-2234 pins, STMicroelectronicsNot recordedSOT-2234 pinsSTMicroelectronics
- What it is
- Not recorded
- Maker
- STMicroelectronics
- Package
- SOT-223
- Pins
- 4
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC6108N42CMRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- CMOS-IC: Voltage Detector 4,2V, 5%, Hst, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6118C32CMR-GSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 3.2V±2%, ±Reset PPO, Sense, Hst 5%
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
5 more parts have no package on record
ESH2PCRectifier, VishayRectifierNot recordedNot recordedVishay
- What it is
- Rectifier
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Diode: Rectifier, 150V, 2A, Vf<0.92V(1A)
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
IXD5108N42CGRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.2V±2%, Hst., -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5118C32CGR-GVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.2V±2%, ±Reset PPO, Sense, Hst. 5%
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6108N42CGRVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 4,2V5%, Hst, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6118C32CGR-GVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.2V±2%, ±Reset PPO, Sense, Hst. 5%
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as P2C
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.