SMD code P4 in SOD-128
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SOD-128 is printed P4
Not sure which one you have?
Answer up to 4 quick questions and these 39 parts are ranked, with a meter test that settles it. It works on a dead part too.
P6SMZ27ATGSOD-128TVS diode, 2 pins, Fagor ElectronicaTVS diode2 pinsFagor Electronica
- What it is
- TVS diode
- Maker
- Fagor Electronica
- Package
- SOD-128
- Pins
- 2
- Details
- Transient voltage supressor: Vrm=23.1V, Vbr=25.7..28.4V, Ipp=16A, 600W
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
14 more parts have no package on record. Nothing rules them out, so they stay.
KRA317EDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA317VDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA567EDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA567UDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA767EDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA767UDigital transistor (PNP, resistors built in), KECDigital transistor (PNP, resistors built in)Not recordedKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
PU2DMHRectifier, Taiwan SemiconductorRectifierNot recordedTaiwan Semiconductor
- What it is
- Rectifier
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
74AUP2G04GFNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP2G04GMNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP2G04GNNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP2G04GSNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP2G04GXNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP3G04GFNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Triple inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP3G04GNNXPNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Triple inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with P4
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 85 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.