SMD code PX in SMAF
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SMAF is printed PX
Not sure which one you have?
Answer up to 4 quick questions and these 18 parts are ranked, with a meter test that settles it. It works on a dead part too.
SMA6F220A-HFSMAFTVS diode, 2 pins, ComchipTVS diode2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMAF
- Pins
- 2
- Details
- 220 V 600 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
14 more parts have no package on record. Nothing rules them out, so they stay.
RSQ015N06HZGN-channel MOSFET, ROHMN-channel MOSFETNot recordedROHM
- What it is
- N-channel MOSFET
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Nch 60V 1.5A Small Signal MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
74LVCE1G86FZ4Diodes IncorporatedNot recordedNot recordedDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-input EXCLUSIVE-OR gate
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AX6644WCTLDO regulator, AXElite TechnologyLDO regulatorNot recordedAXElite Technology
- What it is
- LDO regulator
- Maker
- AXElite Technology
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, Dual out., Vo1/Vo2=1.2V/2.8V±2%, 200mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
IXD1504A371NR-GLDO regulator, IXYSLDO regulatorNot recordedIXYS
- What it is
- LDO regulator
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 3.7V±1%, 150mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
IXD5109N47ANVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.7V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C50ENRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.0V±0.8%, -Reset PPO, -MR, 800ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
R1118K271DRicohNot recordedNot recordedRicoh
- What it is
- Not recorded
- Maker
- Ricoh
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: 2.7V±1%, 150mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
R1225N252CNisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- VR-IC: PWM step-down DC-DC converter, 2,5V, 300KHz
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SMBS200ATVS diode, Formosa MicrosemiTVS diodeNot recordedFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=200V, Vbr=224..247V, Ipp=1.9A, 600W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
SSM3J36MFVToshibaNot recordedNot recordedToshiba
- What it is
- Not recorded
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- p-ch mosfet power sw
- Source
- Published code list
Is it dead? The meter test is below: P-channel MOSFET.
XC6109N47ANVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 4,7V, Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127C50ENRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.0V±0.8%, -Reset PPO, -MR, Rdt=800ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6218P28NLDO regulator, TorexLDO regulatorNot recordedTorex
- What it is
- LDO regulator
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.8V±2%, 200mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
XC6224B281NRLDO regulator, TorexLDO regulatorNot recordedTorex
- What it is
- LDO regulator
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.8V±1.5%, 150mA, +CE, PDR
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with PX
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.