SMD code R in SOD-923
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
8 parts in SOD-923 are printed R
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
CDZCV5.1BSOD-923ESD protection diode, ROHMESD protection diodeROHM
- What it is
- ESD protection diode
- Maker
- ROHM
- Package
- SOD-923
- Pins
- 2
- Details
- Transient Voltage Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD9C3.3SSOD-923ESD protection diode, onsemiESD protection diodeonsemi
- What it is
- ESD protection diode
- Maker
- onsemi
- Package
- SOD-923
- Pins
- 2
- Details
- ESD Protection Diode SERIES
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LNZ9F16VT5GSOD-923Zener diode, LRCZener diodeLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-923
- Pins
- 2
- Details
- Zener diode, VZ Min 15.2 V, VZ Nom 16 V, VZ Max 16.8 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
NSR0340P2SOD-923Schottky diode, onsemiSchottky diodeonsemi
- What it is
- Schottky diode
- Maker
- onsemi
- Package
- SOD-923
- Pins
- 2
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
ESD9C3.3ST5GSOD-923TVS diode, onsemiTVS diodeonsemi
- What it is
- TVS diode
- Maker
- onsemi
- Package
- SOD-923
- Pins
- 2
- Details
- 3.3V Unidirectional TVS Diode
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
MM9D16VSOD-923Zener diode, Weitron TechnologyZener diodeWeitron Technology
- What it is
- Zener diode
- Maker
- Weitron Technology
- Package
- SOD-923
- Pins
- 2
- Details
- Zener diode: 15.20..16.80V, Izt=5mA, Zzt=50, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
NZ9F9V1STSOD-923Zener diode, onsemiZener diodeonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-923
- Pins
- 2
- Details
- Zener diode: 8.85..9.23V, Izt=5mA, Zzt=30, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
NZ9F16VTSOD-923Zener diode, onsemiZener diodeonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-923
- Pins
- 2
- Details
- Zener diode: 15.20..16.80V, Izt=5mA, Zzt=50, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
7 more parts have no package on record. Nothing rules them out, so they stay.
AOZ8S501BDS-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
AOZ8851ADI-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BAR89-02LRHPIN diode, InfineonPIN diodeInfineon
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
CH40N4-40GPSchottky diode, ChenmkoSchottky diodeChenmko
- What it is
- Schottky diode
- Maker
- Chenmko
- Package
- Not recorded
- Pins
- Not recorded
- Details
- SCHOTTKY BARRIER DIODE, 40 V, 0.2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
CPDWZ5V0MSBPA-HFESD protection diode, ComchipESD protection diodeComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 5 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD11LVL5.0CESD protection diode, LRCESD protection diodeLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V, IR @VRWM 0.5 μA, VBR Min 6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD101-B1-02ELESD protection diode, InfineonESD protection diodeInfineon
- What it is
- ESD protection diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with R
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 982 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.