SMD code R1A
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
24 parts are printed R1A
Not sure which one you have?
Answer up to 4 quick questions and these 24 parts are ranked, with a meter test that settles it. It works on a dead part too.
CJ3401ASOT-23P-channel MOSFET, 3 pins, JSCJP-channel MOSFETSOT-233 pinsJSCJ
- What it is
- P-channel MOSFET
- Maker
- JSCJ
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
FMOS3401ASOT-23MOSFET, 3 pins, Formosa MicrosemiMOSFETSOT-233 pinsFormosa Microsemi
- What it is
- MOSFET
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
L3401ALSOT-23P-channel MOSFET, 3 pins, Yangjie Electronic TechP-channel MOSFETSOT-233 pinsYangjie Electronic Tech
- What it is
- P-channel MOSFET
- Maker
- Yangjie Electronic Tech
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
LM4041AIM3-1.2SOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage referenceSOT-233 pinsTexas Instruments
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- Precision Micro Power Shunt Voltage Reference
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
LM4041AIM3X-1.2SOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage referenceSOT-233 pinsTexas Instruments
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- Precision Micro Power Shunt Voltage Reference
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SMS3401A-CSOT-23MOSFET, 3 pins, SeCoSMOSFETSOT-233 pinsSeCoS
- What it is
- MOSFET
- Maker
- SeCoS
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
SST3904SOT-23NPN transistor, 3 pins, ROHMNPN transistorSOT-233 pinsROHM
- What it is
- NPN transistor
- Maker
- ROHM
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
STTH1R02ASMARectifier, 2 pins, STMicroelectronicsRectifierSMA2 pinsSTMicroelectronics
- What it is
- Rectifier
- Maker
- STMicroelectronics
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
UMT3904SOT-323NPN transistor, 3 pins, ROHMNPN transistorSOT-3233 pinsROHM
- What it is
- NPN transistor
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
UMT3904U3SOT-323NPN transistor, 3 pins, ROHMNPN transistorSOT-3233 pinsROHM
- What it is
- NPN transistor
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
CD214A-R150SMARectifier, 2 pins, BournsRectifierSMA2 pinsBourns
- What it is
- Rectifier
- Maker
- Bourns
- Package
- SMA
- Pins
- 2
- Details
- Si-diode: Rect, 50V, 1A, Vf<1V(1A), <12pF
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
IXD5118C41AMR-GSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 4.1V±2%, ±Reset PPO, Sense, Hst 5%, Cd
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
3 more parts have no package on record
SGM836-1.25XTDI6GVoltage supervisor, 6 pins, SG MicroVoltage supervisorNot recorded6 pinsSG Micro
- What it is
- Voltage supervisor
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 6
- Details
- 1.16 V threshold, Microprocessor Supervisory Circuit with Programmable Delay Time
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
ADR391AUJZ-R25 pins, Analog DevicesNot recordedNot recorded5 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- Not recorded
- Pins
- 5
- Source
- Published code list
Is it dead? The meter test is below: This part.
IXD5118C41AGR-GVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.1V±2%, ±Reset PPO, Sense, Hst. 5%, Cd
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as R1A
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.