Skip to content

SMD code R2K

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

R2K is a resistor marking

0.2 Ω

0.2 Ω resistor, 10%

The R stands in for the decimal point, which is how sub-ohm and fractional values are printed. K is the tolerance, ±10%. The same marking also reads as 0.2 µH on an inductor, and nothing in the code says which; the body of the part does.

Other readings of the same characters, most likely first

  • 0.2 µH inductor, 10%

Check it with a meter

Lift one end and measure across it. A good one reads 0.2 Ω within 10%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 0.2 Ω on the board is a fault. Open, or well above 0.2 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 0.2 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23-5, SOT-23, SMB), R2K is a part code instead. Those parts are listed below.

6 parts are printed R2K

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • LMV331IDCKSOT-353Comparator, 5 pins, Texas InstrumentsComparatorSOT-3535 pinsTexas Instruments
    What it is
    Comparator
    Maker
    Texas Instruments
    Package
    SOT-353
    Pins
    5
    Details
    Single, LMV393 Dual, LMV339 Quad General-Purpose Low-Voltage Comparators
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • S-8211DAK-M5T1SOT-23-5Battery protection IC, 5 pins, ABLICBattery protection ICSOT-23-55 pinsABLIC
    What it is
    Battery protection IC
    Maker
    ABLIC
    Package
    SOT-23-5
    Pins
    5
    Details
    BATTERY PROTECTION IC FOR 1-CELL PACK
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • ADR1581BRTZ-R2SOT-233 pins, Analog DevicesNot recordedSOT-233 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • CD214B-R2800SMBRectifier, 2 pins, BournsRectifierSMB2 pinsBourns
    What it is
    Rectifier
    Maker
    Bourns
    Package
    SMB
    Pins
    2
    Details
    Diode: Rectifier, Fast, 800V, 2A, Vf<1V(2A), 25pF
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MMST8598SOT-23PNP transistor, 3 pins, ROHMPNP transistorSOT-233 pinsROHM
    What it is
    PNP transistor
    Maker
    ROHM
    Package
    SOT-23
    Pins
    3
    Details
    Si-pnp: AF, 60V, 200mA, B=100..300, >150MHz
    Source
    Published code list

    Is it dead? The meter test is below: PNP transistor.

  • XC6368F273MRSOT-23-5DC-DC converter, 5 pins, TorexDC-DC converterSOT-23-55 pinsTorex
    What it is
    DC-DC converter
    Maker
    Torex
    Package
    SOT-23-5
    Pins
    5
    Details
    DC/DC voltage converter IC: PWM/PFM st-up, 2.7V±2.5%, 200mA, 300kHz, +CE, soft start
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as R2K

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with R2K

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.