Skip to content

SMD code R3 in SOT-23

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

R3 on a chip resistor

0.3 Ω

0.3 Ω resistor

The R stands in for the decimal point, which is how sub-ohm and fractional values are printed.

Check it with a meter

Lift one end and measure across it. A good one reads 0.3 Ω. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 0.3 Ω on the board is a fault. Open, or well above 0.3 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 0.3 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23-5, SOT-23, SOT-89), R3 is a part code instead. Those parts are listed below.

Not sure which one you have?

Answer up to 4 quick questions and these 33 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZX84-B62SOT-23Zener diode, 3 pins, NexperiaZener diode3 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Pinout
    • 1 anode
    • 2 not connected
    • 3 cathode
    Details
    62 V ±2% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 2SC2351-3SOT-233 pins, NEC ElectronicsNot recorded3 pinsNEC Electronics
    What it is
    Not recorded
    Maker
    NEC Electronics
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Fast-Sw, UHF, 20V, 70mA, 200mW, B=80..160, 4,5Hz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SC2351-QSOT-233 pins, NEC ElectronicsNot recorded3 pinsNEC Electronics
    What it is
    Not recorded
    Maker
    NEC Electronics
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Fast-Sw, UHF, 20V, 70mA, 200mW, B=100..200, 4,5Hz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SC2351QSOT-233 pins, RenesasNot recorded3 pinsRenesas
    What it is
    Not recorded
    Maker
    Renesas
    Package
    SOT-23
    Pins
    3
    Details
    npn RF fT 4.5 GHz hfe 100-200
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SK283-3SOT-233 pins, Sanyo ElectricNot recorded3 pinsSanyo Electric
    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    FET n-type: AF-Amp, 80V, 50mA, 150mW, Idss=1.2..3mA, Up=0.75V
    Source
    Published code list

    Is it dead? The meter test is below: MOSFET.

  • ELM7633LCBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisor3 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2%, -Reset PPO, Rdt=150ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ELM9733CBBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisor3 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2.5%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • KDS115SOT-233 pins, KECNot recorded3 pinsKEC
    What it is
    Not recorded
    Maker
    KEC
    Package
    SOT-23
    Pins
    3
    Details
    series pair band sw diode 30V 50mA
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • NE02133-3SOT-233 pins, California Eastern LaboratoriesNot recorded3 pinsCalifornia Eastern Laboratories
    What it is
    Not recorded
    Maker
    California Eastern Laboratories
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Fast-Sw, UHF, 25V, 70mA, 200mW, B=80..160, 4,5Hz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • NE02133-QSOT-233 pins, California Eastern LaboratoriesNot recorded3 pinsCalifornia Eastern Laboratories
    What it is
    Not recorded
    Maker
    California Eastern Laboratories
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Fast-Sw, UHF, 25V, 70mA, 200mW, B=100..200, 4,5Hz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • R3130N29BA3SOT-233 pins, Nisshinbo Micro DevicesNot recorded3 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 2,9V, -Reset Push-pull output, 100ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • TC54VN5302ECBSOT-23Voltage supervisor, 3 pins, MicrochipVoltage supervisor3 pinsMicrochip
    What it is
    Voltage supervisor
    Maker
    Microchip
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 5.3V±2%, -Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • XC61CN5302MSOT-233 pins, TorexNot recorded3 pinsTorex
    What it is
    Not recorded
    Maker
    Torex
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 5,3V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 2 more parts have no package on record. Nothing rules them out, so they stay.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with R3

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 144 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.