Skip to content

SMD code R5 in SOT-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

R5 on a chip resistor

0.5 Ω

0.5 Ω resistor

The R stands in for the decimal point, which is how sub-ohm and fractional values are printed.

Check it with a meter

Lift one end and measure across it. A good one reads 0.5 Ω. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 0.5 Ω on the board is a fault. Open, or well above 0.5 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 0.5 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23-5, SOT-23, SMB), R5 is a part code instead. Those parts are listed below.

Not sure which one you have?

Answer up to 4 quick questions and these 19 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SRC1205USOT-3233 pins, AukNot recorded3 pinsAuk
    What it is
    Not recorded
    Maker
    Auk
    Package
    SOT-323
    Pins
    3
    Details
    Si-npn-Digi: Sw, 50V, 100mA, 200mW, 200MHz, R1/R2=22/47k
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • ESDL4151MX4ESD protection diode, onsemiESD protection diodeNot recordedonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD and Surge Protection Device, Bidirectional, 15 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • MM5Z24VBZener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • MM5Z24VB-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • 2SC4092RE4 pins, RenesasNot recorded4 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      4
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • BD46E292G-MVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±1%, -MR, -Reset PPO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BFP650F4 pins, InfineonNot recorded4 pinsInfineon
      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      4
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • BZX584B24VZener diode, Tak Cheong SemiconductorZener diodeNot recordedTak Cheong Semiconductor
      What it is
      Zener diode
      Maker
      Tak Cheong Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 23.52..24.48V, Izt=5mA, Zzt=70, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • DW84C6V8NND03Zener diode, JSCJZener diodeNot recordedJSCJ
      What it is
      Zener diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.8V±10%, If=10mA, 150mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • ISL9016IRUCWZ-T6 pins, RenesasNot recorded6 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      6
      Details
      equivalent [1.8/1.2V Dual LDO]
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • IXD1504A451NR-GLDO regulator, IXYSLDO regulatorNot recordedIXYS
      What it is
      LDO regulator
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 4.5V±1%, 150mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • R5426D111DGNisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Li-Ion Battery Over-charge/discharge Protection, Vc/d=1,11V
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • SRC1205EFAukNot recordedNot recordedAuk
      What it is
      Not recorded
      Maker
      Auk
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 150mW, 200MHz, R1/R2=22/47k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • SRC1205UFAukNot recordedNot recordedAuk
      What it is
      Not recorded
      Maker
      Auk
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 200mW, 200MHz, R1/R2=22/47k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • TK11450MTokNot recordedNot recordedTok
      What it is
      Not recorded
      Maker
      Tok
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, CE, 5V±1.5%, 110mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as R5

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with R5

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 127 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.