Skip to content

SMD code RJ in SMA

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 11 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • P4SMA10CASMATVS diode, Fagor ElectronicaTVS diodeFagor Electronica
    What it is
    TVS diode
    Maker
    Fagor Electronica
    Package
    SMA
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • RS1JSMARectifier, General Semiconductor IndustriesRectifierGeneral Semiconductor Industries
    What it is
    Rectifier
    Maker
    General Semiconductor Industries
    Package
    SMA
    Pins
    2
    Details
    Diode: Rectifier, 600V, 1A, Vf<1.3V(1A)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • 9 more parts have no package on record. Nothing rules them out, so they stay.
    • BFCN-3085+RF filter, Mini-CircuitsRF filterMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter, 2800-3400 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • 74AXP1G17GMNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AXP1G17GNNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AXP1G17GSNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AXP1G17GXNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD5348FVEVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,8V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD5348GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,8V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RGF1JRectifier, VishayRectifierVishay
      What it is
      Rectifier
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-diode: Fast Recovery Rect, 600V, 1A, 150..500ns
      Source
      Published code list

      Is it dead? The meter test is below: Silicon diode.

    • RS1PJRectifier, VishayRectifierVishay
      What it is
      Rectifier
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Diode: Rectifier, 600V, 1A, Vf<1.3V(1A)
      Source
      Published code list

      Is it dead? The meter test is below: Silicon diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with RJ

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.