Skip to content

SMD code S

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • APL3527SAWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SBWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SCWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SDWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SEWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SFWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SGWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • APL3527SHWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • ARB521S-40-HFSOD-523Schottky diode, 2 pins, ComchipSchottky diodeSOD-5232 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOD-523
    Pins
    2
    Details
    40 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BA592SOD-323Diode, 2 pins, InfineonDiodeSOD-3232 pinsInfineon
    What it is
    Diode
    Maker
    Infineon
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • BAP64-02SOD-523PIN diode, 2 pins, NXPPIN diodeSOD-5232 pinsNXP
    What it is
    PIN diode
    Maker
    NXP
    Package
    SOD-523
    Pins
    2
    Details
    1 Product profile 2 Pinning information 3 Ordering information
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • BB535SOD-3232 pins, InfineonNot recordedSOD-3232 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: This part.

  • BB639SOD-3232 pins, InfineonNot recordedSOD-3232 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: This part.

  • 2 more parts have no package on record
    • ACDSZC01100-HFSwitching diode, ComchipSwitching diodeNot recordedNot recordedComchip
      What it is
      Switching diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      100 V, 100 mA switching diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • AOZ8310DI-26ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      ESD protection diode
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as S

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 15 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.