Skip to content

SMD code S4

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • TSD103AWSSOD-323Schottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-3232 pinsGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-323
    Pins
    2
    Details
    0.35A, 40V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • WSR3003D5SOD-523Schottky diode, 2 pins, WayonSchottky diodeSOD-5232 pinsWayon
    What it is
    Schottky diode
    Maker
    Wayon
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • ZHCS350WTSOD-523Schottky diode, 2 pins, DiotecSchottky diodeSOD-5232 pinsDiotec
    What it is
    Schottky diode
    Maker
    Diotec
    Package
    SOD-523
    Pins
    2
    Details
    SMD Low Barrier Schottky Rectifier Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 1SS367SOD-1232 pins, ToshibaNot recordedSOD-1232 pinsToshiba
    What it is
    Not recorded
    Maker
    Toshiba
    Package
    SOD-123
    Pins
    2
    Details
    Si-diode: Schottky, Sw, 15V, 100mA
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • 1SS373SOD-323Schottky diode, 2 pins, ToshibaSchottky diodeSOD-3232 pinsToshiba
    What it is
    Schottky diode
    Maker
    Toshiba
    Package
    SOD-323
    Pins
    2
    Details
    Si-diode: Schottky, Sw, 15V, 100mA
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • 2SA813-4SOT-23PNP transistor, 3 pins, NEC ElectronicsPNP transistorSOT-233 pinsNEC Electronics
    What it is
    PNP transistor
    Maker
    NEC Electronics
    Package
    SOT-23
    Pins
    3
    Details
    PNP transistor: GP, 60V, 200mA, 150mW, B=120..240, 200MHz
    Source
    Published code list

    Is it dead? The meter test is below: PNP transistor.

  • 2SC3361-4SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric
    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Sw, Hi-Sp, 60V, 150mA, 150mW, 100MHz, B=100..200
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • APX803-44SRSOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
    What it is
    Voltage supervisor
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 4.38V±1.5%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • APX803S-44SRSOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
    What it is
    Voltage supervisor
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 4.38V±1.5%, -Reset ODO, Rdt=240ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AX6906FASOT-323Voltage supervisor, 3 pins, AXElite TechnologyVoltage supervisorSOT-3233 pinsAXElite Technology
    What it is
    Voltage supervisor
    Maker
    AXElite Technology
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 2.63V±1.5%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BBQ31ASOT-233 pins, Diodes IncorporatedNot recordedSOT-233 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: HF, 30V, 100mA, 330mW, B>100, >600MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 4 more parts have no package on record
    • SUF14MRectifier, SeCoSRectifierNot recordedNot recordedSeCoS
      What it is
      Rectifier
      Maker
      SeCoS
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • TPS22915BYFPLoad switch, 4 pins, Texas InstrumentsLoad switchNot recorded4 pinsTexas Instruments
      What it is
      Load switch
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      5.5V, 2A, 37mΩ On-Resistance Load Switch
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Load switch.

    • TSD034-101WSSchottky diode, Taitron ComponentsSchottky diodeNot recordedNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diodes (Two Terminals)
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • 1PS89SS043 pins, NexperiaNot recordedNot recorded3 pinsNexperia
      What it is
      Not recorded
      Maker
      Nexperia
      Package
      Not recorded
      Pins
      3
      Details
      Si-diode: Dual, Schottky Barrier, U-Speed, 85V, 200mA, <1,5pF
      Source
      Published code list

      Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.