SMD code S8 in SOD-123
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
10 parts in SOD-123 are printed S8
Not sure which one you have?
Answer up to 4 quick questions and these 29 parts are ranked, with a meter test that settles it. It works on a dead part too.
1N4148SOD-123Switching diode, 2 pins, UnisonicSwitching diodeSOD-1232 pinsUnisonic
- What it is
- Switching diode
- Maker
- Unisonic
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAT43WSOD-123Schottky diode, 2 pins, AiT SemiconductorSchottky diodeSOD-1232 pinsAiT Semiconductor
- What it is
- Schottky diode
- Maker
- AiT Semiconductor
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BAT43W-CSOD-123Schottky diode, 2 pins, SeCoSSchottky diodeSOD-1232 pinsSeCoS
- What it is
- Schottky diode
- Maker
- SeCoS
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BAT43W-P2-HFSOD-123Schottky diode, 2 pins, ComchipSchottky diodeSOD-1232 pinsComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- SOD-123
- Pins
- 2
- Details
- 30 V, 0.2 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
GSBAT43WSOD-123Schottky diode, 2 pins, Good-ArkSchottky diodeSOD-1232 pinsGood-Ark
- What it is
- Schottky diode
- Maker
- Good-Ark
- Package
- SOD-123
- Pins
- 2
- Details
- Schottky diode, 30 V, 200 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RB751W-40SOD-123Schottky diode, 2 pins, YFWSchottky diodeSOD-1232 pinsYFW
- What it is
- Schottky diode
- Maker
- YFW
- Package
- SOD-123
- Pins
- 2
- Details
- 0.03A, 40V, Surface Mount Small Signal Schottky Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SD103CWSOD-123Schottky diode, 2 pins, Taitron ComponentsSchottky diodeSOD-1232 pinsTaitron Components
- What it is
- Schottky diode
- Maker
- Taitron Components
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SFM18-MSOD-123Rectifier, 2 pins, Formosa MicrosemiRectifierSOD-1232 pinsFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- SOD-123
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SMD24SGPSOD-123Schottky diode, 2 pins, ChenmkoSchottky diodeSOD-1232 pinsChenmko
- What it is
- Schottky diode
- Maker
- Chenmko
- Package
- SOD-123
- Pins
- 2
- Details
- SCHOTTKY BARRIER RECTIFIER, 40 V, 1.5 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SMD24SPTSOD-123Schottky diode, 2 pins, Chenmko EnterpriseSchottky diodeSOD-1232 pinsChenmko Enterprise
- What it is
- Schottky diode
- Maker
- Chenmko Enterprise
- Package
- SOD-123
- Pins
- 2
- Details
- Diode: SBR, 40V, 1.5A, Vf<0.65V(1.1A)
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
5 more parts have no package on record. Nothing rules them out, so they stay.
BAR88-099LRHPIN diode, InfineonPIN diodeNot recordedNot recordedInfineon
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
BZT52C15KZener diode, Taiwan SemiconductorZener diodeNot recordedNot recordedTaiwan Semiconductor
- What it is
- Zener diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MFPS8SSchottky diode, Taitron ComponentsSchottky diodeNot recordedNot recordedTaitron Components
- What it is
- Schottky diode
- Maker
- Taitron Components
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Surface Mount Schottky Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MM5Z15V-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SFM18-MHRectifier, Formosa MicrosemiRectifierNot recordedNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as S8
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.