Skip to content

SMD code SHs

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and SH was searched.

54 parts are printed SHs

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • B2020WSOD-123Schottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-1232 pinsGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123
    Pins
    2
    Details
    2A, 20V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • B2020WSSOD-323Schottky diode, 2 pins, JSCJSchottky diodeSOD-3232 pinsJSCJ
    What it is
    Schottky diode
    Maker
    JSCJ
    Package
    SOD-323
    Pins
    2
    Details
    Schottky diode, 20 V, 2 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • BZX84J-B24SOD-323Zener diode, 2 pins, NexperiaZener diodeSOD-3232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Pinout
    • 1 cathode
    • 2 anode
    Details
    24 V ±2% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CDBV220-HFSOD-323Schottky diode, 2 pins, ComchipSchottky diodeSOD-3232 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOD-323
    Pins
    2
    Details
    20 V, 2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • CDBV340-HFSOD-323Schottky diode, 2 pins, ComchipSchottky diodeSOD-3232 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOD-323
    Pins
    2
    Details
    40 V, 3 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • JSPD160ASOD-323Schottky diode, 2 pins, JieJieSchottky diodeSOD-3232 pinsJieJie
    What it is
    Schottky diode
    Maker
    JieJie
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • JSPD1160ASOD-123Schottky diode, 2 pins, JieJieSchottky diodeSOD-1232 pinsJieJie
    What it is
    Schottky diode
    Maker
    JieJie
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • LTVS8H5.0T5GSOD-882ESD protection diode, 2 pins, LRCESD protection diodeSOD-8822 pinsLRC
    What it is
    ESD protection diode
    Maker
    LRC
    Package
    SOD-882
    Pins
    2
    Details
    ESD protection diode, VRWM 5 V, IR @VRWM 1 μA, VBR Min 6 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PSBD3D60V1HSOD-323Schottky diode, 2 pins, PrisemiSchottky diodeSOD-3232 pinsPrisemi
    What it is
    Schottky diode
    Maker
    Prisemi
    Package
    SOD-323
    Pins
    2
    Details
    Schottky diode, 60 V, 1 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • SGM826B-2.7XC4GSOT-343Voltage supervisor, 4 pins, SG MicroVoltage supervisorSOT-3434 pinsSG Micro
    What it is
    Voltage supervisor
    Maker
    SG Micro
    Package
    SOT-343
    Pins
    4
    Details
    Small Package, High Precision Voltage Detectors with Internal Delay Time Circuit
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • SMAJ130SMATVS diode, 2 pins, DOWOTVS diodeSMA2 pinsDOWO
    What it is
    TVS diode
    Maker
    DOWO
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMV1129-079LFSOD-523Varicap diode, 2 pins, SkyworksVaricap diodeSOD-5232 pinsSkyworks
    What it is
    Varicap diode
    Maker
    Skyworks
    Package
    SOD-523
    Pins
    2
    Details
    SMV1129-079LF: Hyperabrupt Junction Tuning Varactor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • 3 more parts have no package on record

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as SHs

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 29 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.