SMD code T26
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
27 parts are printed T26
Not sure which one you have?
Answer up to 4 quick questions and these 27 parts are ranked, with a meter test that settles it. It works on a dead part too.
TPT29306L1-DFGRDFNLogic level translator, 8 pins, 3PEAKLogic level translatorDFN8 pins3PEAK
- What it is
- Logic level translator
- Maker
- 3PEAK
- Package
- DFN
- Pins
- 8
- Details
- Dual Bidirectional I2C Bus and SMBus Voltage-Level Translator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
TPT29336-T8TRSOT-23-8Logic level translator, 8 pins, 3PEAKLogic level translatorSOT-23-88 pins3PEAK
- What it is
- Logic level translator
- Maker
- 3PEAK
- Package
- SOT-23-8
- Pins
- 8
- Details
- Dual Bidirectional I3C Bus and I2C/SMBus Voltage-level Translator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
ADT6502SRJZP045RL7SOT-23-55 pins, Analog DevicesNot recordedSOT-23-55 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23-5
- Pins
- 5
- Source
- Published code list
Is it dead? The meter test is below: This part.
HD74LV2GT126AUSSSOPRenesasNot recordedSSOPNot recordedRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SSOP
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual bus buffer with 3-state output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
KIC77E26T2SOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.6V±1%, -Reset ODO, Rdt=400ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
PDTC123ETSOT-23Digital transistor (NPN, resistors built in), 3 pins, NXPDigital transistor (NPN, resistors built in)SOT-233 pinsNXP
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- NXP
- Package
- SOT-23
- Pins
- 3
- Details
- 50 V, 100 mA NPN resistor-equipped transistor; R1 = 2.2 kΩ, R2 = 2.2 kΩ
- Source
- Published code list
Is it dead? The meter test is below: Digital transistor.
PDTC123JTSOT-23Digital transistor (NPN, resistors built in), 3 pins, NXPDigital transistor (NPN, resistors built in)SOT-233 pinsNXP
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- NXP
- Package
- SOT-23
- Pins
- 3
- Details
- 50 V, 100 mA NPN resistor-equipped transistor; R1 = 2.2 kΩ, R2 = 47 kΩ
- Source
- Published code list
Is it dead? The meter test is below: Digital transistor.
R1162N261DSOT-23-55 pins, RicohNot recordedSOT-23-55 pinsRicoh
- What it is
- Not recorded
- Maker
- Ricoh
- Package
- SOT-23-5
- Pins
- 5
- Details
- VR-IC: LDO, CE, auto discharge, 2.6V±2%, 350mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
RP202N261DSOT-23-5LDO regulator, 5 pins, RicohLDO regulatorSOT-23-55 pinsRicoh
- What it is
- LDO regulator
- Maker
- Ricoh
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.6V±1%, 200mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
6 more parts have no package on record
MBRXT260Schottky diode, Galaxy MicroelectronicsSchottky diodeNot recordedNot recordedGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2A, 60V, Surface Mount Schottky Barrier Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
74HC2GT126GDNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual bus buffer with 3-state output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74HCT1G126GVNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Bus buffer gate with 3-state output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74HCT2G126DCNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual bus buffer with 3-state output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74HCT2G126DPNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual bus buffer with 3-state output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
KIC77E26M2Voltage supervisor, KECVoltage supervisorNot recordedNot recordedKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.6V±1%, -Reset ODO, Rdt=400ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as T26
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.