SMD code T2s
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and T2 was searched.
95 parts are printed T2s
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BAV20WS-HFSOD-323Switching diode, 2 pins, ComchipSwitching diodeSOD-3232 pinsComchip
- What it is
- Switching diode
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 200 V, 200 mA switching diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20WSFLSOD-323Switching diode, 2 pins, YFWSwitching diodeSOD-3232 pinsYFW
- What it is
- Switching diode
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20WTSOD-523Switching diode, 2 pins, YFWSwitching diodeSOD-5232 pinsYFW
- What it is
- Switching diode
- Maker
- YFW
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BCX18SOT-23PNP transistor, 3 pins, Taitron ComponentsPNP transistorSOT-233 pinsTaitron Components
- What it is
- PNP transistor
- Maker
- Taitron Components
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
BZX84-C27SOT-23Zener diode, 3 pins, NexperiaZener diodeSOT-233 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Pinout
- 1 anode
- 2 not connected
- 3 cathode
- Details
- 27 V approx. ±5% voltage regulator (Zener) diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX384-C10SOD-323Zener diode, 2 pins, NexperiaZener diodeSOD-3232 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CHEMT2GPSOT-563Dual PNP transistor, 6 pins, ChenmkoDual PNP transistorSOT-5636 pinsChenmko
- What it is
- Dual PNP transistor
- Maker
- Chenmko
- Package
- SOT-563
- Pins
- 6
- Details
- Dual Silicon Transistor, 50 V, 150 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor pair.
CPDQT12VHT-HFSOD-882ESD protection diode, 2 pins, ComchipESD protection diodeSOD-8822 pinsComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- SOD-882
- Pins
- 2
- Details
- 12 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
MM3Z2V4SSOD-323Zener diode, 2 pins, onsemiZener diodeSOD-3232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-323
- Pins
- 2
- Details
- 2.4V, 400mW, Surface Mount Zener Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z2V4SSOD-523Zener diode, 2 pins, onsemiZener diodeSOD-5232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-523
- Pins
- 2
- Details
- Zener Voltage Regulators MM5ZxxxST1G Series, SZMM5ZxxxST1G Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMBD6050SOT-23Switching diode, 3 pins, Taitron ComponentsSwitching diodeSOT-233 pinsTaitron Components
- What it is
- Switching diode
- Maker
- Taitron Components
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
MMSZ2V7SOD-123Zener diode, 2 pins, onsemiZener diodeSOD-1232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-123
- Pins
- 2
- Details
- Zener Voltage Regulators MMSZxxxT1G Series, SZMMSZxxxT1G Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
3 more parts have no package on record
ESDA07CP30ESD protection diode, LeiditechESD protection diodeNot recordedNot recordedLeiditech
- What it is
- ESD protection diode
- Maker
- Leiditech
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 7 V, Cj 15 pF
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDBLM12VB1ESD protection diode, JSCJESD protection diodeNot recordedNot recordedJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LNP2010DT2AGP-channel MOSFET, LRCP-channel MOSFETNot recordedNot recordedLRC
- What it is
- P-channel MOSFET
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- MOSFET, Complementary N&P-Channel, VDSS 20 V, VGS 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor pair
Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.