Skip to content

SMD code TV

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 47 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 74HCT2G17GWSOT-3636 pins, NXPNot recordedSOT-3636 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-363
    Pins
    6
    Details
    CMOS logic IC: Dual buffer with Schmitt-trigger input
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74LVC1G11DWSOT-3636 pins, Diodes IncorporatedNot recordedSOT-3636 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-363
    Pins
    6
    Details
    CMOS logic IC: 3-input AND gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74LVC1G11W6SOT-23-66 pins, Diodes IncorporatedNot recordedSOT-23-66 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23-6
    Pins
    6
    Details
    CMOS logic IC: 3-input AND gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ASM162TEUSSOT-1434 pins, AliNot recordedSOT-1434 pinsAli
    What it is
    Not recorded
    Maker
    Ali
    Package
    SOT-143
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 3.08V, -MR, Reset Open Drain Output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BAT54TSPTSOT-416Schottky diode, 3 pins, Chenmko EnterpriseSchottky diodeSOT-4163 pinsChenmko Enterprise
    What it is
    Schottky diode
    Maker
    Chenmko Enterprise
    Package
    SOT-416
    Pins
    3
    Details
    Diode: Dual, SBR, 30V, 200mA, Vf<1V(100mA), 5ns
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • CD214A-T9.0CASMATVS diode, 2 pins, BournsTVS diodeSMA2 pinsBourns
    What it is
    TVS diode
    Maker
    Bourns
    Package
    SMA
    Pins
    2
    Details
    TVS: 9.0V, 26.0A, 400W(1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • MMBF112LSOT-233 pins, onsemiNot recordedSOT-233 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    RF jfet
    Source
    Published code list

    Is it dead? The meter test is below: JFET.

  • P4SMAJ9.0ACSMA2 pins, PanjitNot recordedSMA2 pinsPanjit
    What it is
    Not recorded
    Maker
    Panjit
    Package
    SMA
    Pins
    2
    Details
    TVS: 9V, 26A, 400W (1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P4SMAJ9.0CASMA2 pins, PanjitNot recordedSMA2 pinsPanjit
    What it is
    Not recorded
    Maker
    Panjit
    Package
    SMA
    Pins
    2
    Details
    TVS: 9.0V, 26.0A, 400W(1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 6 more parts have no package on record
    • 74HCT2G17GVNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC1G11FW4Diodes IncorporatedNot recordedNot recordedNot recordedDiodes Incorporated
      What it is
      Not recorded
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 3-input AND gate
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC1G11FZ4Diodes IncorporatedNot recordedNot recordedNot recordedDiodes Incorporated
      What it is
      Not recorded
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 3-input AND gate
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD45451GVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,5V, -Reset Open drain output, 100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C48HNRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.8V±0.8%, +Reset PPO, -MR, 200ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • LT4ME9.0CATVS diode, Lite-On SemiconductorTVS diodeNot recordedNot recordedLite-On Semiconductor
      What it is
      TVS diode
      Maker
      Lite-On Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=9.0V, Vbr=10.0..11.1V, Ipp=26.0A, 400W(1ms), Bidir.
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

JFET

Ohms range for drain to source, diode range for the gate, part lifted.

Working, it reads

Drain to source conducts both ways at a few hundred ohms, depending on the part, and some meters beep on it. The gate reads one junction to drain and to source, about 0.6 to 0.7 V, and open the other way.

Dead, it reads

  • The gate the same both ways to drain or source, near 0 V with a continuous beep: gate shorted.
  • Drain to source open: the channel has failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
Drain to source resistance varies from part to part. An identical part elsewhere on the board shows what is normal.
Watch for:
A good channel can beep like a short between drain and source. That is normal; the gate junction says whether it has failed.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.