73 parts are printed UE-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 2SC2821-ESOT-23NPN transistor, 3 pins, RenesasNPN transistorSOT-233 pinsRenesas
    What it is
    NPN transistor
    Maker
    Renesas
    Package
    SOT-23
    Pins
    3
    Details
    NPN transistor: GP, 20V, 50mA, 150mW, B=400..800, 230MHz
    Source
    Published code list

    Is it dead? The meter test is below: NPN transistor.

  • 2SC5212-ESOT-893 pins, Isahaya ElectronicsNot recordedSOT-893 pinsIsahaya Electronics
    What it is
    Not recorded
    Maker
    Isahaya Electronics
    Package
    SOT-89
    Pins
    3
    Details
    Si-npn: Rel-Drv, 25V, 1A, 500mW, 180MHz, B=150..300
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • APE8865U5-20SOT-353LDO regulator, 5 pins, Advanced Power ElectronicsLDO regulatorSOT-3535 pinsAdvanced Power Electronics
    What it is
    LDO regulator
    Maker
    Advanced Power Electronics
    Package
    SOT-353
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 2.0±2%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • AX6608-20A5SOT-353LDO regulator, 5 pins, AXElite TechnologyLDO regulatorSOT-3535 pinsAXElite Technology
    What it is
    LDO regulator
    Maker
    AXElite Technology
    Package
    SOT-353
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 2.0V±2%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • AX6608-20BSOT-23-5LDO regulator, 5 pins, AXElite TechnologyLDO regulatorSOT-23-55 pinsAXElite Technology
    What it is
    LDO regulator
    Maker
    AXElite Technology
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 2.0V±2%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • AX6608-20Z6DFNLDO regulator, AXElite TechnologyLDO regulatorDFNNot recordedAXElite Technology
    What it is
    LDO regulator
    Maker
    AXElite Technology
    Package
    DFN
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 2.0V±2%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • CD214A-T12CASMATVS diode, 2 pins, BournsTVS diodeSMA2 pinsBourns
    What it is
    TVS diode
    Maker
    Bourns
    Package
    SMA
    Pins
    2
    Details
    TVS: 12V, 20.1A, 400W(1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 8 more parts have no package on record
    • AP7341D-33FS4-7LDO regulator, Diodes IncorporatedLDO regulatorNot recordedNot recordedDiodes Incorporated
      What it is
      LDO regulator
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 3.3V±1%, 300mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • APE8865U4-20LDO regulator, Advanced Power ElectronicsLDO regulatorNot recordedNot recordedAdvanced Power Electronics
      What it is
      LDO regulator
      Maker
      Advanced Power Electronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 2.0±2%, 300mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • AX6608-20SCLDO regulator, AXElite TechnologyLDO regulatorNot recordedNot recordedAXElite Technology
      What it is
      LDO regulator
      Maker
      AXElite Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 2.0V±2%, 300mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • BD45E235G-MVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.3V±1%, -MR, -Reset ODO, Rdt=50ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD45261GVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,6V, -Reset Open drain output, 100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • CZRER6V8B-HZener diode, ComchipZener diodeNot recordedNot recordedComchip
      What it is
      Zener diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.63 6.972V, Zzt=8, Izt=5mA, 150mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • CZRF6V8BZener diode, ComchipZener diodeNot recordedNot recordedComchip
      What it is
      Zener diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.63..6.97V, Izt=5mA, Zzt=8, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • CZRQR6V8BZener diode, ComchipZener diodeNot recordedNot recordedComchip
      What it is
      Zener diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.63..6.97V, Izt=5mA, Zzt=8, 125mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?