SMD code US in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
3 parts in SOT-23 are printed US
Not sure which one you have?
Answer up to 4 quick questions and these 35 parts are ranked, with a meter test that settles it. It works on a dead part too.
LBZB84C10LT1GSOT-23Zener diode, LRCZener diodeLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 9.4 V, VZ Nom 10 V, VZ Max 10.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LBZB84C10LT1GSOT-23Zener diode, LRCZener diodeLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 9.4 V, VZ Nom 10 V, VZ Max 10.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZB84-C10SOT-23Zener diode, NXPZener diodeNXP
- What it is
- Zener diode
- Maker
- NXP
- Package
- SOT-23
- Pins
- 3
- Details
- Dual Zener diodes
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
12 more parts have no package on record. Nothing rules them out, so they stay.
ACZRQC20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V 0.125 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ACZRUC20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20.5 V 0.15 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BAR88-099L4PIN diode, InfineonPIN diodeInfineon
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
CZRFR20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V 0.2 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CZRQC20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V 0.125 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CZRU20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V 0.15 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CZRUR20VB-HFZener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V 0.15 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ECH8695R-TL-WDual N-channel MOSFET, onsemiDual N-channel MOSFETonsemi
- What it is
- Dual N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Power MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET pair.
KDS123ESwitching diode, KECSwitching diodeKEC
- What it is
- Switching diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
KDS123USwitching diode, KECSwitching diodeKEC
- What it is
- Switching diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
KDS127ESwitching diode, KECSwitching diodeKEC
- What it is
- Switching diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
TSD011-367WTSchottky diode, Taitron ComponentsSchottky diodeTaitron Components
- What it is
- Schottky diode
- Maker
- Taitron Components
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diodes (Two Terminals)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET pair
Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as US
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.