Skip to content

SMD code V14 in SOD-123F

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

2 parts in SOD-123F are printed V14

Not sure which one you have?

Answer up to 4 quick questions and these 13 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • GVS14FLSOD-123FSchottky diode, Galaxy MicroelectronicsSchottky diodeGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123F
    Pins
    2
    Details
    1A, 40V, Surface Mount Schottky Barrier Rectifiers
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • GVS14FL-VSOD-123FSchottky diode, Galaxy MicroelectronicsSchottky diodeGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123F
    Pins
    2
    Details
    1A, 40V, Surface Mount Schottky Barrier Rectifiers
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 11 more parts have no package on record. Nothing rules them out, so they stay.
    • 74LVC1G14GVNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverter with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC1G17GVNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Buffer with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC2G14GVNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC3G14DCNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Triple inverting buffer with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC3G14DPNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Triple inverting buffer with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC3G14GDNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Triple inverting buffer with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC3G14GMNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Triple inverting buffer with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC3G14GTNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Triple inverting buffer with Schmitt-trigger inputs
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • DZ23B9V1-VZener diode, VishayZener diodeVishay
      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2.7V Dual Zener Diodes
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • DZ23C9V1-VZener diode, VishayZener diodeVishay
      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      9.1V Dual Zener Diodes
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • TZT9V1CWZener diodeZener diodeNot recorded
      What it is
      Zener diode
      Maker
      Not recorded
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SMD Zener Diodes (Three Terminals) - 300mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.