Skip to content

SMD code V3 in SMB

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 18 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • FES2DSMB2 pins, FagNot recorded2 pinsFag
    What it is
    Not recorded
    Maker
    Fag
    Package
    SMB
    Pins
    2
    Details
    Si-diode: Ultrafast Recovery, 200V, 2A, <50ns
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • NCV8177BMX120LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear Voltage Regulator, Fast Transient Response, 500 mA with Enable
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCV8177BMX120TCG-A642LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear Voltage Regulator, Fast Transient Response, 500 mA with Enable
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • 2SK1332-3Sanyo ElectricNot recordedNot recordedSanyo Electric
      What it is
      Not recorded
      Maker
      Sanyo Electric
      Package
      Not recorded
      Pins
      Not recorded
      Details
      n-FET: AF-Amp, 30V, 20mA, 150mW, Idss=1.2..3mA
      Source
      Published code list

      Is it dead? The meter test is below: MOSFET.

    • 74LVC1G53GFNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC1G53GNNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC1G53GSNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC2G53GFNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC2G53GNNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74LVC2G53GSNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-channel analog multiplexer/demultiplexer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD45292GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,9V, -Reset Open drain output, 200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BFG25AW/XRRF transistor, PhilipsRF transistorNot recordedPhilips
      What it is
      RF transistor
      Maker
      Philips
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: VHF/UHF-Amp, 8V, 6.5mA, 200mW, B>50..200, 5GHz
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • BZA956AVL5 pins, Philips SemiconductorsNot recorded5 pinsPhilips Semiconductors
      What it is
      Not recorded
      Maker
      Philips Semiconductors
      Package
      Not recorded
      Pins
      5
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • DZ23B3V3-VZener diode, VishayZener diodeNot recordedVishay
      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2.7V Dual Zener Diodes
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • ISL9021AIRUJZ-T6 pins, RenesasNot recorded6 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      6
      Details
      equivalent [2.8V LDO]
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with V3

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 12 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.