Skip to content

SMD code WG in SOD-882

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 15 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZT52C11LSOD-882Zener diode, 2 pins, Galaxy MicroelectronicsZener diode2 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-882
    Pins
    2
    Details
    11V, 100mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • NLSV4T3144MULogic level translator, onsemiLogic level translatorNot recordedonsemi
      What it is
      Logic level translator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      4-Bit Dual-Supply Non-Inverting Level Translator
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • RW4E045ATP-channel MOSFET, ROHMP-channel MOSFETNot recordedROHM
      What it is
      P-channel MOSFET
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Pch -30V -4.5A Power MOSFET
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: P-channel MOSFET.

    • SMAFJ6.0CATVS diode, Blue RocketTVS diodeNot recordedBlue Rocket
      What it is
      TVS diode
      Maker
      Blue Rocket
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SMAHFL6.0CATVS diode, Formosa MicrosemiTVS diodeNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SMF6.0CA-MFLTVS diode, Formosa MicrosemiTVS diodeNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • AX5505R24DC-DC converterDC-DC converterNot recordedNot recorded
      What it is
      DC-DC converter
      Maker
      Not recorded
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Micropower VFM Synchronous Step-up DC/DC Converter
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AX5505R48DC-DC converterDC-DC converterNot recordedNot recorded
      What it is
      DC-DC converter
      Maker
      Not recorded
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Micropower VFM Synchronous Step-up DC/DC Converter
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BCR116L3Digital transistor (NPN, resistors built in), InfineonDigital transistor (NPN, resistors built in)Not recordedInfineon
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 250mW, R1/R2=4.7k/47k, 150MHz
      Source
      Published code list

      Is it dead? The meter test is below: Digital transistor.

    • BD46341GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 3,4V, -Reset Push-pull output, 100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • LT4ME58CATVS diode, Lite-On SemiconductorTVS diodeNot recordedLite-On Semiconductor
      What it is
      TVS diode
      Maker
      Lite-On Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=58V, Vbr=64.4..71.2V, Ipp=4.3A, 400W(1ms), Bidir.
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • RP300K42ABVoltage supervisor, RicohVoltage supervisorNot recordedRicoh
      What it is
      Voltage supervisor
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.2V±1%, -Reset ODO, -MR, Rdt=50ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • SMAS6.0CATVS diode, Formosa MicrosemiTVS diodeNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=6.0V, Vbr=6.67..7.37V, Ipp=38.0A, 400W(1ms), Bidir.
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SMF4L58CAQTVS diode, Diodes IncorporatedTVS diodeNot recordedDiodes Incorporated
      What it is
      TVS diode
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=58V, Vbr=64.4..71.2V, Ipp=4.3A, 400W(1ms), Bidir.
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • µPA653TT6 pins, RenesasNot recorded6 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      6
      Source
      Published code list

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

P-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as WG

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with WG

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 14 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.