Skip to content

SMD code X7s

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and X7 was searched.

3 parts are printed X7s

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • AO3407ASOT-23P-channel MOSFET, 3 pins, Alpha & Omega Semiconductor
    What it is
    P-channel MOSFET
    Maker
    Alpha & Omega Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    P-channel MOSFET (8-60 V)
    Source
    From the manufacturer's datasheet

    Is it dead? The meter test is below: P-channel MOSFET.

  • AO3407ALSOT-23P-channel MOSFET, 3 pins, Alpha & Omega Semiconductor
    What it is
    P-channel MOSFET
    Maker
    Alpha & Omega Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    P-channel MOSFET (8-60 V)
    Source
    From the manufacturer's datasheet

    Is it dead? The meter test is below: P-channel MOSFET.

  • BSD316SNSOT-363N-channel MOSFET, 6 pins, Infineon
    What it is
    N-channel MOSFET
    Maker
    Infineon
    Package
    SOT-363
    Pins
    6
    Details
    N-Channel Small Signal MOSFET 30 V in SOT363 package
    Source
    From the manufacturer's datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

P-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as X7s

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with X7s

For a marking with its end worn or burnt off. Each code has a page of its own.

Open this in the search to correct a character or try another package.