SMD code X9-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
40 parts are printed X9-
Not sure which one you have?
Answer up to 4 quick questions and these 40 parts are ranked, with a meter test that settles it. It works on a dead part too.
BAS21HGPSOD-323Switching diode, 2 pins, ChenmkoSwitching diodeSOD-3232 pinsChenmko
- What it is
- Switching diode
- Maker
- Chenmko
- Package
- SOD-323
- Pins
- 2
- Details
- FAST SWITCHING DIODE, 250 V, 200 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAT42WSSOD-323Schottky diode, 2 pins, Formosa MicrosemiSchottky diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BAT42WS-Q1SOD-323Schottky diode, 2 pins, Formosa MicrosemiSchottky diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BSD235CSOT-363Complementary MOSFET pair (N-channel and P-channel), 6 pins, InfineonComplementary MOSFET pair (N-channel and P-channel)SOT-3636 pinsInfineon
- What it is
- Complementary MOSFET pair (N-channel and P-channel)
- Maker
- Infineon
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET pair.
BZX7B16SOD-723Zener diode, 2 pins, Good-ArkZener diodeSOD-7232 pinsGood-Ark
- What it is
- Zener diode
- Maker
- Good-Ark
- Package
- SOD-723
- Pins
- 2
- Details
- Zener diode, VZ 16 V, 0.1 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX84-C33,215SOT-23Zener diode, 3 pins, HXYZener diodeSOT-233 pinsHXY
- What it is
- Zener diode
- Maker
- HXY
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, 75 V, 0.05 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX84C33SOT-23Zener diode, 3 pins, DiotecZener diodeSOT-233 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX84C33-Q1SOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX784B10SOD-723Zener diode, 2 pins, SeCoSZener diodeSOD-7232 pinsSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- SOD-723
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX784C10SOD-723Zener diode, 2 pins, SeCoSZener diodeSOD-7232 pinsSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- SOD-723
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
GZF110CSOD-123FZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Zener diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 110V, 5%, Surface Mount Zener Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SZMM3Z4V3SOD-323Zener diode, 2 pins, onsemiZener diodeSOD-3232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-323
- Pins
- 2
- Details
- Zener Voltage Regulators MM3ZxxxT1G Series, SZMM3ZxxxT1G Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TGZF110CSOD-123FZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Zener diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 110V, 5%, Surface Mount Zener Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
VS30VUA1LAMSOD-128TVS diode, 2 pins, ROHMTVS diodeSOD-1282 pinsROHM
- What it is
- TVS diode
- Maker
- ROHM
- Package
- SOD-128
- Pins
- 2
- Details
- Transient Voltage Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
VS30VUA1LAMTFSOD-128TVS diode, 2 pins, ROHMTVS diodeSOD-1282 pinsROHM
- What it is
- TVS diode
- Maker
- ROHM
- Package
- SOD-128
- Pins
- 2
- Details
- Transient Voltage Suppressor (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET pair
Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as X9-
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with X9-
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 28 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.