SMD code Y3y
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, y, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and Y3 was searched.
87 parts are printed Y3y
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
ACZRT55C13-GSOT-23Zener diode, 3 pins, ComchipZener diodeSOT-233 pinsComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode: 12.4..14.1V, Izt=5.0mA, Zzt=30, 350mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
AD8420ARMZMSOP-88 pins, Analog DevicesNot recordedMSOP-88 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- MSOP-8
- Pins
- 8
- Source
- Published code list
Is it dead? The meter test is below: This part.
APX809-44SRSOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 4.38V±1.5%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
APX809S-44SR-7SOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 4.38V±1.5%, -Reset PPO, Rdt=240ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BAP70-02SOD-523PIN diode, 2 pins, NXPPIN diodeSOD-5232 pinsNXP
- What it is
- PIN diode
- Maker
- NXP
- Package
- SOD-523
- Pins
- 2
- Details
- 1 Product profile 2 Pinning information 3 Ordering information
- Source
- An older or alternative marking, from a published code list
Is it dead? The meter test is below: PIN diode or varicap.
BZF10C9V1SOD-123FZener diode, 2 pins, Diodesemi TechnologyZener diodeSOD-123F2 pinsDiodesemi Technology
- What it is
- Zener diode
- Maker
- Diodesemi Technology
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener diode: 8.6..9.6V, Izt=28mA, Zzt=5, 1W
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
9 more parts have no package on record
ZGFM109V1B-MST-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
74LVC1G123DCNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123DPNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123GDNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123GFNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123GNNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123GSNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74LVC1G123GTNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Retriggerable monostable multivibrator with Schmitt-trigger iInput
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BD46E362G-MVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.6V±1%, -MR, -Reset PPO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.