Skip to content

SMD code Y4p

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and Y4 was searched.

99 parts are printed Y4p

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ACZRT55C15-GSOT-23Zener diode, 3 pins, ComchipZener diodeSOT-233 pinsComchip
    What it is
    Zener diode
    Maker
    Comchip
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: 13.8..15.6V, Izt=5.0mA, Zzt=30, 350mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • APX809-40SRSOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
    What it is
    Voltage supervisor
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 4.0V±1.5%, -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • APX809S-40SR-7SOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisorSOT-233 pinsDiodes Incorporated
    What it is
    Voltage supervisor
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 4.0V±1.5%, -Reset PPO, Rdt=240ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BAP64-02SOD-523PIN diode, 2 pins, NXPPIN diodeSOD-5232 pinsNXP
    What it is
    PIN diode
    Maker
    NXP
    Package
    SOD-523
    Pins
    2
    Details
    1 Product profile 2 Pinning information 3 Ordering information
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • BZF10C10SOD-123FZener diode, 2 pins, Diodesemi TechnologyZener diodeSOD-123F2 pinsDiodesemi Technology
    What it is
    Zener diode
    Maker
    Diodesemi Technology
    Package
    SOD-123F
    Pins
    2
    Details
    Zener diode: 9.5..10.5V, Izt=25mA, Zzt=7, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZT52-C15TSOD-5232 pins, Micro Commercial ComponentsNot recordedSOD-5232 pinsMicro Commercial Components
    What it is
    Not recorded
    Maker
    Micro Commercial Components
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 15V±5%, Izt=5mA, Zzt=30Ω, 100mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • BZT52C3V3-V-GSOD-123Zener diode, 2 pins, VishayZener diodeSOD-1232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode: 3.3V±5%, Izt=5mA, Zzt=95, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZT52C15TSOD-523Zener diode, 2 pins, Micro Commercial ComponentsZener diodeSOD-5232 pinsMicro Commercial Components
    What it is
    Zener diode
    Maker
    Micro Commercial Components
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 15V±5%, Izt=5mA, Zzt=30Ω, 150mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZV49-C15SOT-893 pins, Diodes IncorporatedNot recordedSOT-893 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-89
    Pins
    3
    Details
    Z-diode: 15V±5%, Izt=5mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • BZV49C15SOT-893 pinsNot recordedSOT-893 pinsNot recorded
    What it is
    Not recorded
    Maker
    Not recorded
    Package
    SOT-89
    Pins
    3
    Details
    1W zener 15V ±5%
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX84-A15SOT-23Zener diode, 3 pins, Central SemiconductorZener diodeSOT-233 pinsCentral Semiconductor
    What it is
    Zener diode
    Maker
    Central Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    15 V ±1% voltage regulator (Zener) diode
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX84-B15SOT-23Zener diode, 3 pins, Central SemiconductorZener diodeSOT-233 pinsCentral Semiconductor
    What it is
    Zener diode
    Maker
    Central Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    15 V ±2% voltage regulator (Zener) diode
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 3 more parts have no package on record
    • 74LVC2G74GSNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: D-type flip-flop with preset and clear
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • ADXL377BCPZ-RL16 pins, Analog DevicesNot recordedNot recorded16 pinsAnalog Devices
      What it is
      Not recorded
      Maker
      Analog Devices
      Package
      Not recorded
      Pins
      16
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • BD46E372G-MVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.7V±1%, -MR, -Reset PPO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.