Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and Y6 was searched.

78 parts are printed Y6p

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZX84-C18-VSOT-233 pins, Central SemiconductorNot recordedSOT-233 pinsCentral Semiconductor
    What it is
    Not recorded
    Maker
    Central Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Z-diode: 18V±5%, Zzt=10Ω(45mA), 300mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • BZX84C18LT1SOT-23Zener diode, 3 pins, onsemiZener diodeSOT-233 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: 16.8..19.1V, Zzt=45, Izt=5mA, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX84C18LT1GSOT-23Zener diode, 3 pins, onsemiZener diodeSOT-233 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX88-C18SOT-233 pins, Ferranti SemiconductorsNot recordedSOT-233 pinsFerranti Semiconductors
    What it is
    Not recorded
    Maker
    Ferranti Semiconductors
    Package
    SOT-23
    Pins
    3
    Details
    Z-diode: 18V±5%, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • BZX384C3V9-V-GSOD-323Zener diode, 2 pins, VishayZener diodeSOD-3232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode: 3.9V±5%, Izt=5mA, Zzt=85, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CMDZ5258BSOD-323Zener diode, 2 pins, Central SemiconductorZener diodeSOD-3232 pinsCentral Semiconductor
    What it is
    Zener diode
    Maker
    Central Semiconductor
    Package
    SOD-323
    Pins
    2
    Details
    Z-diode: 36V±5%, 3.4mA, Zzt=70Ω, 250mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CMSZDA18VSOT-323Zener diode, 3 pinsZener diodeSOT-3233 pinsNot recorded
    What it is
    Zener diode
    Maker
    Not recorded
    Package
    SOT-323
    Pins
    3
    Details
    Z-diode: Dual, 16.8..19.1V, Zzt=45Ω, 9.2mA, 275mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CZRT55C18SOT-23Zener diode, 3 pins, ComchipZener diodeSOT-233 pinsComchip
    What it is
    Zener diode
    Maker
    Comchip
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: 16.8..19.1V, Zzt=45, Izt=5mA, 350mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • ECG5027SMSOT-233 pins, EcgNot recordedSOT-233 pinsEcg
    What it is
    Not recorded
    Maker
    Ecg
    Package
    SOT-23
    Pins
    3
    Details
    Z-diode: 18V±5%, 300mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • ELM7646LBBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-233 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 4.6V±2%, -Reset PPO, Rdt=500ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • FMY6SOT-23-55 pinsNot recordedSOT-23-55 pinsNot recorded
    What it is
    Not recorded
    Maker
    Not recorded
    Package
    SOT-23-5
    Pins
    5
    Details
    Si-n/p: Dual, GP, 40V, 500mA, 200 (250)MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • MFPZ4742ASOD-123FZener diode, 2 pins, Taitron ComponentsZener diodeSOD-123F2 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-123F
    Pins
    2
    Details
    Zener diode: 11.4..12.6V, Izt=21.0mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 3 more parts have no package on record
    • BZX84C18-VZener diode, VishayZener diodeNot recordedNot recordedVishay
      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • CGY62RF amplifier (MMIC), 6 pins, InfineonRF amplifier (MMIC)Not recorded6 pinsInfineon
      What it is
      RF amplifier (MMIC)
      Maker
      Infineon
      Package
      Not recorded
      Pins
      6
      Details
      GaAs MMIC
      Source
      Published code list

      Is it dead? The meter test is below: RF amplifier.

    • CGY1206 pins, InfineonNot recordedNot recorded6 pinsInfineon
      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      6
      Details
      GaAs MMIC
      Source
      Published code list

      Is it dead? The meter test is below: RF amplifier.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

RF amplifier

Voltage, board powered, on the output pin that the bias resistor or choke feeds.

Working, it reads

The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

Dead, it reads

  • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
  • Output pin at the full supply voltage: open inside, no current flowing.
On the board:
Measured on the board with power on; the bias network is part of the reading.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The figures depend on the part and its bias resistor. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.