Skip to content

SMD code YS-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

58 parts are printed YS-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 2SD601-SSOT-233 pins, PanNot recordedSOT-233 pinsPan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: GP, AF, 50V, 600mA, B=290..460, 150MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SD2216-SSOT-4163 pins, PanNot recordedSOT-4163 pinsPan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOT-416
    Pins
    3
    Details
    Si-npn: GP, 60V, 200mA, 125mW, 150MHz, B=290..460
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 74AHC1G02SESOT-3535 pins, Diodes IncorporatedNot recordedSOT-3535 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-353
    Pins
    5
    Details
    CMOS logic IC: 2-input NOR gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AHC1G02W5SOT-23-55 pins, Diodes IncorporatedNot recordedSOT-23-55 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS logic IC: 2-input NOR gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BZT52C27-V-GSOD-123Zener diode, 2 pins, VishayZener diodeSOD-1232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode: 27V±5%, Izt=5mA, Zzt=80, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX284-C3V6MicroMELF2 pins, NexperiaNot recordedMicroMELF2 pinsNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    MicroMELF
    Pins
    2
    Details
    0.4W zener 3.6V E12 ±5%
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX384C27-V-GSOD-323Zener diode, 2 pins, VishayZener diodeSOD-3232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode: 27V±5%, Izt=2mA, Zzt=25, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • DDZ9V1CSOD-123Zener diode, 2 pins, Diodes IncorporatedZener diodeSOD-1232 pinsDiodes Incorporated
    What it is
    Zener diode
    Maker
    Diodes Incorporated
    Package
    SOD-123
    Pins
    2
    Details
    Z-diode: 9,1V±5%, Izt=20mA, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • DDZ9V1CSSOD-323Zener diode, 2 pins, Diodes IncorporatedZener diodeSOD-3232 pinsDiodes Incorporated
    What it is
    Zener diode
    Maker
    Diodes Incorporated
    Package
    SOD-323
    Pins
    2
    Details
    Z-diode: 9,1V±5%%, Izt=20mA, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • DDZ9V1CSFSOD-323Zener diode, 2 pins, Diodes IncorporatedZener diodeSOD-3232 pinsDiodes Incorporated
    What it is
    Zener diode
    Maker
    Diodes Incorporated
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode: 8.83..9.30V, Izt=20mA, Zzt=30, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 5 more parts have no package on record
    • 2SD874ANPN transistorNPN transistorNot recordedNot recordedNot recorded
      What it is
      NPN transistor
      Maker
      Not recorded
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Published code list

      Is it dead? The meter test is below: NPN transistor.

    • 74AUP1G14FS3Diodes IncorporatedNot recordedNot recordedNot recordedDiodes Incorporated
      What it is
      Not recorded
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverter with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4225FVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,5V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4225FWEVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,5V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4225GVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2,5V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.