  • SMAJ48CA-Q1SMAFTVS diode, 2 pins, Formosa MicrosemiTVS diodeSMAF2 pinsFormosa Microsemi
    What it is
    TVS diode
    Maker
    Formosa Microsemi
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMAJ48CA-SSMATVS diode, 2 pins, ProTek DevicesTVS diodeSMA2 pinsProTek Devices
    What it is
    TVS diode
    Maker
    ProTek Devices
    Package
    SMA
    Pins
    2
    Details
    400 Watt TVS Component
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMV2019-079LFSOD-523Varicap diode, 2 pins, SkyworksVaricap diodeSOD-5232 pinsSkyworks
    What it is
    Varicap diode
    Maker
    Skyworks
    Package
    SOD-523
    Pins
    2
    Details
    Tuning Varactors
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • TV04A480JB-HFSMATVS diode, 2 pins, ComchipTVS diodeSMA2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMA
    Pins
    2
    Details
    48 V 400 W bidirectional TVS diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • H1SMA48CAT3SMATVS diode, 2 pins, HXYTVS diodeSMA2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • HSMAJ48CA13FSMATVS diode, 2 pins, HXYTVS diodeSMA2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • HSZ1SMA48CAT3SMATVS diode, 2 pins, HXYTVS diodeSMA2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMAJ48CA-13-FSMATVS diode, 2 pins, HXYTVS diodeSMA2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SZ1SMA48CAT3GSMATVS diode, 2 pins, HXYTVS diodeSMA2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 74AHC1G86SESOT-3535 pins, Diodes IncorporatedNot recordedSOT-3535 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-353
    Pins
    5
    Details
    CMOS logic IC: 2-input EXCLUSIVE-OR gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AHC1G86W5SOT-23-55 pins, Diodes IncorporatedNot recordedSOT-23-55 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS logic IC: 2-input EXCLUSIVE-OR gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 4 more parts have no package on record
    • SMF48CA-MFLTVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • 74AUP1G86FS3Diodes IncorporatedNot recordedNot recordedNot recordedDiodes Incorporated
      What it is
      Not recorded
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input EXCLUSIVE-OR gate
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4230FVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 3V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4230FWEVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 3V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.