SMD marking
Zin SOD-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
8 parts are printed Z
Not sure which one you have?
Answer up to 4 quick questions and these 8 parts are ranked, with a meter test that settles it. It works on a dead part too.
ESDBL7V0D3SOD-323ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 7 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
7 more parts have no package on record. Nothing rules them out, so they stay.
AOC2804BDual N-channel MOSFET, Alpha & Omega SemiconductorDual N-channel MOSFETAlpha & Omega Semiconductor
- What it is
- Dual N-channel MOSFET
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Common-drain dual N-channel battery MOSFET
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board:
- On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8S327UD4-05ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8858DI-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESDBL7V0A1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 7 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESDBL7V0AE1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 7.5 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESDBL7V0AH1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 7 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PMEG4005AESFSchottky diode, NexperiaSchottky diodeNexperia
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- Not recorded
- Pins
- 2
- Details
- 40 V, 0.5 A low VF MEGA Schottky barrier rectifier
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
10 more parts are printed with a code easy to misread as Z
Printed with a code easy to misread
One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.
RB500V-40Hprinted 2SOD-323Schottky diode, Taiwan SemiconductorSchottky diodeTaiwan Semiconductor
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- Schottky diode
- Maker
- Taiwan Semiconductor
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
9 more parts have no package on record. Nothing rules them out, so they stay.
AOZ8S303BLS-03printed 2ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8S516UDS-36printed 2ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8251BDI-16printed 2ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8831DT-24printed 2ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BAR64-03Wprinted 2PIN diode, InfineonPIN diodeInfineon
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BAS3010B-03Wprinted 2Switching diode, InfineonSwitching diodeInfineon
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- Switching diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BB439printed 2InfineonNot recordedInfineon
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESD113-B1-02ELSprinted 2ESD protection diode, InfineonESD protection diodeInfineon
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PESD5V0L1USFprinted 2ESD protection diode, NexperiaESD protection diodeNexperia
Printed 2 on the part. Easy to misread as Z. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Nexperia
- Package
- Not recorded
- Pins
- 2
- Details
- Low capacitance unidirectional ESD protection diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
32 more parts have codes that begin with Z
Codes that begin with Z
For a marking with its end worn or burnt off. Each one shows its full printed code.
all SOD-323, 2 pins. What differs:
CESD5V0D3printed ZASOD-323ESD protection diode, JSCJESD protection diodeJSCJ
Printed ZA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 5 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
CESD12VD3printed ZCSOD-323ESD protection diode, JSCJESD protection diodeJSCJ
Printed ZC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 12 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
CESD24VD3printed ZYSOD-323ESD protection diode, JSCJESD protection diodeJSCJ
Printed ZY. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 24 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MM3Z4B3printed Z0SOD-323Zener diode, DiotecZener diodeDiotec
Printed Z0. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOD-323
- Pins
- 2
- Details
- SMD Planar Zener Diodes
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ4.7Bprinted Z7SOD-323Zener diode, PanjitZener diodePanjit
Printed Z7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ4.7B-AUprinted Z7SOD-323Zener diode, PanjitZener diodePanjit
Printed Z7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ5.1Bprinted Z8SOD-323Zener diode, PanjitZener diodePanjit
Printed Z8. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ5.1B-AUprinted Z8SOD-323Zener diode, PanjitZener diodePanjit
Printed Z8. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ5.6Bprinted Z9SOD-323Zener diode, PanjitZener diodePanjit
Printed Z9. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ5.6B-AUprinted Z9SOD-323Zener diode, PanjitZener diodePanjit
Printed Z9. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ6.2Bprinted ZASOD-323Zener diode, PanjitZener diodePanjit
Printed ZA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ6.2B-AUprinted ZASOD-323Zener diode, PanjitZener diodePanjit
Printed ZA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ6.8Bprinted ZBSOD-323Zener diode, PanjitZener diodePanjit
Printed ZB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ6.8B-AUprinted ZBSOD-323Zener diode, PanjitZener diodePanjit
Printed ZB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ7.5Bprinted ZCSOD-323Zener diode, PanjitZener diodePanjit
Printed ZC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ7.5B-AUprinted ZCSOD-323Zener diode, PanjitZener diodePanjit
Printed ZC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ8.2Bprinted ZDSOD-323Zener diode, PanjitZener diodePanjit
Printed ZD. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ8.2B-AUprinted ZDSOD-323Zener diode, PanjitZener diodePanjit
Printed ZD. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ9.1Bprinted ZESOD-323Zener diode, PanjitZener diodePanjit
Printed ZE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ9.1B-AUprinted ZESOD-323Zener diode, PanjitZener diodePanjit
Printed ZE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ10Bprinted ZFSOD-323Zener diode, PanjitZener diodePanjit
Printed ZF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ10B-AUprinted ZFSOD-323Zener diode, PanjitZener diodePanjit
Printed ZF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ11Bprinted ZGSOD-323Zener diode, PanjitZener diodePanjit
Printed ZG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ11B-AUprinted ZGSOD-323Zener diode, PanjitZener diodePanjit
Printed ZG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ12Bprinted ZHSOD-323Zener diode, PanjitZener diodePanjit
Printed ZH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ12B-AUprinted ZHSOD-323Zener diode, PanjitZener diodePanjit
Printed ZH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ13Bprinted ZJSOD-323Zener diode, PanjitZener diodePanjit
Printed ZJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ13B-AUprinted ZJSOD-323Zener diode, PanjitZener diodePanjit
Printed ZJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ15Bprinted ZKSOD-323Zener diode, PanjitZener diodePanjit
Printed ZK. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ15B-AUprinted ZKSOD-323Zener diode, PanjitZener diodePanjit
Printed ZK. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ16Bprinted ZLSOD-323Zener diode, PanjitZener diodePanjit
Printed ZL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ16B-AUprinted ZLSOD-323Zener diode, PanjitZener diodePanjit
Printed ZL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Open this in the search to correct a character or try another package.