Skip to content

SMD code ZD- in SOT-416

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

No part printed ZD- is recorded in SOT-416

Not sure which one you have?

Answer up to 4 quick questions and these 19 parts are ranked, with a meter test that settles it. It works on a dead part too.

15 parts have no package on record. Nothing rules them out, so they stay.

  • BFU730LXRF transistor, 3 pins, NXPRF transistor3 pinsNXP
    What it is
    RF transistor
    Maker
    NXP
    Package
    Not recorded
    Pins
    3
    Details
    NPN wideband silicon germanium RF transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • CURN101-HFRectifier, ComchipRectifierNot recordedComchip
    What it is
    Rectifier
    Maker
    Comchip
    Package
    Not recorded
    Pins
    Not recorded
    Details
    200 V, 1 A rectifier
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • ESD5Z2.5T1GESD protection diode, UMWESD protection diodeNot recordedUMW
    What it is
    ESD protection diode
    Maker
    UMW
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • MM3Z8V2CW-CZener diode, SeCoSZener diodeNot recordedSeCoS
    What it is
    Zener diode
    Maker
    SeCoS
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • NCP360MULoad switch, onsemiLoad switchNot recordedonsemi
    What it is
    Load switch
    Maker
    onsemi
    Package
    Not recorded
    Pins
    Not recorded
    Details
    USB Positive Overvoltage Protection Controller with Internal PMOS FET and Status FLAG
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • ZGFM1056B-MSZener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • ZGFM1056B-MS-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • ZGFM1056B-MSTZener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • ZGFM1056B-MST-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 55GN01FARF transistor, onsemiRF transistorNot recordedonsemi
    What it is
    RF transistor
    Maker
    onsemi
    Package
    Not recorded
    Pins
    Not recorded
    Details
    PNP transistor: RF, 20V, 70mA, 250mW, B=100..160, 4.5GHz
    Source
    Published code list

    Is it dead? The meter test is below: Bipolar transistor.

  • 55GN01FA-TL-E3 pins, onsemiNot recorded3 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    Not recorded
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BU4236FVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 3,6V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU4236FWEVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 3,6V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU4236GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 3,6V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • KDZ2.7VVZener diode, KECZener diodeNot recordedKEC
    What it is
    Zener diode
    Maker
    KEC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode: 2.50..2.90V, Izt=5mA, Zzt=110,, 100mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as ZD-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 21 more parts.

Did you find your part?