Skip to content

SMD code ZKN

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

4 parts are printed ZKN

Not sure which one you have?

Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • CHTA27ZGPSOT-223NPN transistor, ChenmkoNPN transistorSOT-223Not recordedChenmko
    What it is
    NPN transistor
    Maker
    Chenmko
    Package
    SOT-223
    Pins
    Not recorded
    Details
    NPN SILICON Transistor, 60 V, 0.5 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • SMAZKC24SMAZener diode, 2 pins, JieJieZener diodeSMA2 pinsJieJie
    What it is
    Zener diode
    Maker
    JieJie
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • SMAZKC24AUSMAZener diode, 2 pins, JieJieZener diodeSMA2 pinsJieJie
    What it is
    Zener diode
    Maker
    JieJie
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CHTA27ZPTSOT-223Darlington transistor, Chenmko EnterpriseDarlington transistorSOT-223Not recordedChenmko Enterprise
    What it is
    Darlington transistor
    Maker
    Chenmko Enterprise
    Package
    SOT-223
    Pins
    Not recorded
    Details
    NPN darlington: AF, Sw, 60V, 500mA B>10000, 125MHz
    Source
    Published code list

    Is it dead? The meter test is below: Darlington transistor.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Darlington transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the collector and about 1.1 to 1.4 V to the emitter, two junctions in series, and open the other way round. Collector to emitter reads open. Built-in resistors can change these readings.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as ZKN

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with ZKN

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 5 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.