Skip to content

SMD code search: identify a part by its marking

4 parts are printed 10O. 189 printed with a similar-looking code.

Not sure which one you have?

Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.

LDO regulator. What differs:

  • APL5101-30SOT-233 pins, AnpecSOT-233 pinsAnpec
    What it is
    LDO regulator
    Maker
    Anpec
    Package
    SOT-23
    Pins
    3
    Details
    150mA, 4µA Quiescent Current Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SGM2085-0.75QN5GSOT-23-55 pins, SG MicroSOT-23-55 pinsSG Micro
    What it is
    LDO regulator
    Maker
    SG Micro
    Package
    SOT-23-5
    Pins
    5
    Details
    Automotive, 300mA, Low Noise, High PSRR, Low IQ and Low Dropout Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • APL5101-30AISOT-233 pins, Anpec ElectronicsSOT-233 pinsAnpec Electronics
    What it is
    LDO regulator
    Maker
    Anpec Electronics
    Package
    SOT-23
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 3.0V±2%, 150mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • APL5101-30BISOT-23-55 pins, Anpec ElectronicsSOT-23-55 pinsAnpec Electronics
    What it is
    LDO regulator
    Maker
    Anpec Electronics
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 3.0V±2%, 150mA, +CE
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

189 more parts are printed with a code easy to misread as 10O

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • 1.5SMC100printed 100SMCTVS diode, 2 pins, HottechTVS diodeSMC2 pinsHottech

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Hottech
    Package
    SMC
    Pins
    2
    Details
    TVS diode, VRWM 81 V, unidirectional
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0SMC100printed 100SMCTVS diode, 2 pins, YFWTVS diodeSMC2 pinsYFW

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    YFW
    Package
    SMC
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • APL5101-19printed 10DSOT-23LDO regulator, 3 pins, AnpecLDO regulatorSOT-233 pinsAnpec

    Printed 10D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Anpec
    Package
    SOT-23
    Pins
    3
    Details
    150mA, 4µA Quiescent Current Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • APL5101-32printed 10QSOT-23LDO regulator, 3 pins, AnpecLDO regulatorSOT-233 pinsAnpec

    Printed 10Q on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Anpec
    Package
    SOT-23
    Pins
    3
    Details
    150mA, 4µA Quiescent Current Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C2V4printed 100SOD-523Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-5232 pinsFormosa Microsemi

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C2V7printed 100SOD-523Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-5232 pinsFormosa Microsemi

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LM3480IM3-15printed L0DSOT-23LDO regulator, 3 pins, Texas InstrumentsLDO regulatorSOT-233 pinsTexas Instruments

    Printed L0D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    SOT-23
    Pins
    3
    Details
    100-mA, SOT-23, Quasi Low-Dropout Linear Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LM3480IM3X-15printed L0DSOT-23LDO regulator, 3 pins, Texas InstrumentsLDO regulatorSOT-233 pinsTexas Instruments

    Printed L0D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    SOT-23
    Pins
    3
    Details
    100-mA, SOT-23, Quasi Low-Dropout Linear Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMBD5004BRMprinted 10DSOT-23-6Switching diode, 6 pins, Galaxy MicroelectronicsSwitching diodeSOT-23-66 pinsGalaxy Microelectronics

    Printed 10D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOT-23-6
    Pins
    6
    Details
    0.225A, 400V, Surface Mount Small Signal Switching Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • NCP561SN28printed LDDSOT-23-5LDO regulator, 5 pins, onsemiLDO regulatorSOT-23-55 pinsonsemi

    Printed LDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    onsemi
    Package
    SOT-23-5
    Pins
    5
    Details
    150 mA CMOS Low Iq Low-Dropout Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • P6SMBF100printed 100SMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    YFW
    Package
    SMBF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SGM2085-2.5QN5Gprinted 10QSOT-23-5LDO regulator, 5 pins, SG MicroLDO regulatorSOT-23-55 pinsSG Micro

    Printed 10Q on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    SG Micro
    Package
    SOT-23-5
    Pins
    5
    Details
    Automotive, 300mA, Low Noise, High PSRR, Low IQ and Low Dropout Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SGM2240-3.0XKC3Gprinted 1Q0SOT-223LDO regulator, 3 pins, SG MicroLDO regulatorSOT-2233 pinsSG Micro

    Printed 1Q0 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    SG Micro
    Package
    SOT-223
    Pins
    3
    Details
    3.0 V output, 1A, Low Dropout Positive Fixed and Adjustable Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMA2EZ100D5printed 100SMAZener diode, 2 pins, HXYZener diodeSMA2 pinsHXY

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    HXY
    Package
    SMA
    Pins
    2
    Details
    Zener diode, 24 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SML4764printed 100SMAZener diode, 2 pins, VishayZener diodeSMA2 pinsVishay

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SMA
    Pins
    2
    Details
    100 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SN74AHCT1G00DCKprinted 1QOSOT-353Logic gate, 5 pins, Texas InstrumentsLogic gateSOT-3535 pinsTexas Instruments

    Printed 1QO on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Logic gate
    Maker
    Texas Instruments
    Package
    SOT-353
    Pins
    5
    Details
    Single 2-Input Positive-NAND Gate
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SN74LV1T125DCKprinted 1QQSOT-353Logic gate, 5 pins, Texas InstrumentsLogic gateSOT-3535 pinsTexas Instruments

    Printed 1QQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Logic gate
    Maker
    Texas Instruments
    Package
    SOT-353
    Pins
    5
    Details
    Single Power Supply Single Buffer Gate with 3-State Output CMOS Logic Level Shifter
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TLV9064IRUCprinted 1DDQFNOperational amplifier, 14 pins, Texas InstrumentsOperational amplifierQFN14 pinsTexas Instruments

    Printed 1DD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Operational amplifier
    Maker
    Texas Instruments
    Package
    QFN
    Pins
    14
    Details
    10MHz, RRIO, CMOS Operational Amplifiers for Cost-Sensitive Systems
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TLZ10Dprinted 10DSOD-80Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-802 pinsTaitron Components

    Printed 10D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-80
    Pins
    2
    Details
    SMD Zener Diodes (Leadless ) - 500mW
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPL803150-89TRprinted LDDSOT-89LDO regulator, 3 pins, 3PEAKLDO regulatorSOT-893 pins3PEAK

    Printed LDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    3PEAK
    Package
    SOT-89
    Pins
    3
    Details
    40-V 300-mA Wide-Input Ultra-Low Quiescent Current Low-Dropout
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPL803150-S5TRprinted LDDSOT-23-5LDO regulator, 5 pins, 3PEAKLDO regulatorSOT-23-55 pins3PEAK

    Printed LDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    3PEAK
    Package
    SOT-23-5
    Pins
    5
    Details
    40-V 300-mA Wide-Input Ultra-Low Quiescent Current Low-Dropout
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPL803150-ST4R-Sprinted LDDSOT-223LDO regulator, 3 pins, 3PEAKLDO regulatorSOT-2233 pins3PEAK

    Printed LDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    3PEAK
    Package
    SOT-223
    Pins
    3
    Details
    40-V 300-mA Wide-Input Ultra-Low Quiescent Current Low-Dropout
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPL803150Q-ST4R-Sprinted LDDSOT-223LDO regulator, 3 pins, 3PEAKLDO regulatorSOT-2233 pins3PEAK

    Printed LDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    3PEAK
    Package
    SOT-223
    Pins
    3
    Details
    42-V 300-mA Wide-input Ultra-low Quiescent Current Low-Dropout
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TU1ZA100printed 100SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    100V, 5%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TU1ZB100printed 100SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    100V, 10%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • U1ZA100printed 100SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    100V, 5%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • U1ZB100printed 100SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics

    Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    100V, 10%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SC4083-Qprinted 1DQSOT-323RF transistor, 3 pins, ROHMRF transistorSOT-3233 pinsROHM

    Printed 1DQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    RF transistor
    Maker
    ROHM
    Package
    SOT-323
    Pins
    3
    Details
    Si-npn: VHF/UHF, 20V, 50mA, 200mW, B=120..270, 3.2GHz
    Source
    Published code list

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SK198-Qprinted 1OQSOT-233 pins, PanasonicNot recordedSOT-233 pinsPanasonic

    Printed 1OQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Panasonic
    Package
    SOT-23
    Pins
    3
    Details
    FET n-type: AF, LN, 30V, +20mA, 150mA, Idss=2..6mA, Up<1.5V
    Source
    Published code list

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SK662-Qprinted 1OQSOT-3233 pins, PanasonicNot recordedSOT-3233 pinsPanasonic

    Printed 1OQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Panasonic
    Package
    SOT-323
    Pins
    3
    Details
    FET n-type: Small Signal Amp., 30V, 20mA, 150mW, Idss=2..6mA, Up<0.8V
    Source
    Published code list

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0GSMDJ5.0Cprinted IDDSMCTVS diode, 2 pins, Good-ArkTVS diodeSMC2 pinsGood-Ark

    Printed IDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Good-Ark
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=5.0V, Vbr=6.40..7.55V, Ipp=312.5A, 3000W(1ms), Bidir.
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0GSMDJ8.0Cprinted IDQSMCTVS diode, 2 pins, Good-ArkTVS diodeSMC2 pinsGood-Ark

    Printed IDQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Good-Ark
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=8.0V, Vbr=8.89..11.3V, Ipp=200.0A, 3000W(1ms), Bidir.
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0SMCJ5.0Cprinted IDDSMCTVS diode, 2 pins, PanjitTVS diodeSMC2 pinsPanjit

    Printed IDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Panjit
    Package
    SMC
    Pins
    2
    Details
    TVS: 5V, 312.5A, 3000W (1ms), Bidirectional
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0SMCJ8.0Cprinted IDQSMCTVS diode, 2 pins, PanjitTVS diodeSMC2 pinsPanjit

    Printed IDQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Panjit
    Package
    SMC
    Pins
    2
    Details
    TVS: 8V, 200A, 3000W (1ms), Bidirectional
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0SMI5.0Cprinted IDDSMCTVS diode, 2 pins, SMC Diode SolutionsTVS diodeSMC2 pinsSMC Diode Solutions

    Printed IDD on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    SMC Diode Solutions
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vbr=6.4..7.55V, Vrwm=5.0V, 312.5A, 3000W(1ms), Bidir.
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3.0SMI8.0Cprinted IDQSMCTVS diode, 2 pins, SMC Diode SolutionsTVS diodeSMC2 pinsSMC Diode Solutions

    Printed IDQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    SMC Diode Solutions
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vbr=8.89..11.30V, Vrwm=8.0V, 200A, 3000W(1ms), Bidir.
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 10 more parts have no package on record
    • ACGRAT101L-HFprinted 10DRectifier, ComchipRectifierNot recordedNot recordedComchip

      Printed 10D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Rectifier
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      200 V, 1 A rectifier
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways: failed open.
      • A reading the wrong way round as well: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX584B2V4printed 100Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi

      Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX584B2V7printed 100Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi

      Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • IRFR120printed 100Transistor, Taitron ComponentsTransistorNot recordedNot recordedTaitron Components

      Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Transistor
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SMD Signal DMOS Transistor (N-Channel)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ10Dprinted 10DZener diode, VishayZener diodeNot recordedNot recordedVishay

      Printed 10D on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      10 V Zener diode
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2080-1.5QTGC6Gprinted 1QOLDO regulator, 6 pins, SG MicroLDO regulatorNot recorded6 pinsSG Micro

      Printed 1QO on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      6
      Details
      Automotive 500mA, Fast Transient Response, Noise and High Accuracy LDO with Power-Good
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2080-2.5QTGC6Gprinted 1QQLDO regulator, 6 pins, SG MicroLDO regulatorNot recorded6 pinsSG Micro

      Printed 1QQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      6
      Details
      Automotive 500mA, Fast Transient Response, Noise and High Accuracy LDO with Power-Good
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2084-0.8QTGC6Gprinted 1OQLDO regulator, 6 pins, SG MicroLDO regulatorNot recorded6 pinsSG Micro

      Printed 1OQ on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      6
      Details
      Automotive 1A, Fast Transient Response, Noise and High Accuracy LDO with Power-Good
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2092-ADJXGprinted 1O0LDO regulator, 6 pins, SG MicroLDO regulatorNot recorded6 pinsSG Micro

      Printed 1O0 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      6
      Details
      500mA, Fast Transient Response, Low Voltage, Low Noise and Low Dropout Linear Regulator
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 1PMT4100printed 100Zener diode, Microsemi Integrated Products DivisionZener diodeNot recordedNot recordedMicrosemi Integrated Products Division

      Printed 100 on the part. Easy to misread as 10O. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Microsemi Integrated Products Division
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 7.5V±5%, Izt=111.5mA, 1W
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

143 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play
  • Coming soon to the App Store