Skip to content

SMD code search: identify a part by its marking

105 parts are printed 55.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BAT17-05SOT-23Schottky diode, 3 pins, InfineonSchottky diodeSOT-233 pinsInfineon
    What it is
    Schottky diode
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52B3V9LSOD-882Zener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-8822 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-882
    Pins
    2
    Details
    3.9V, 100mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX84-A3V9SOT-23Zener diode, 3 pins, NexperiaZener diodeSOT-233 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    3.9 V ±1% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584B3V9SOD-523Zener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-5232 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C3V9SOD-523Zener diode, 2 pins, Yangjie Electronic TechZener diodeSOD-5232 pinsYangjie Electronic Tech
    What it is
    Zener diode
    Maker
    Yangjie Electronic Tech
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C3V9QSOD-523Zener diode, 2 pins, Yangjie Electronic TechZener diodeSOD-5232 pinsYangjie Electronic Tech
    What it is
    Zener diode
    Maker
    Yangjie Electronic Tech
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C20SOD-523Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-5232 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX584C22SOD-523Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-5232 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTA023EEBSOT-416Digital transistor (PNP, resistors built in), 3 pins, ROHMDigital transistor (PNP, resistors built in)SOT-4163 pinsROHM
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    ROHM
    Package
    SOT-416
    Pins
    3
    Details
    PNP -100mA -50V Digital Transistor (Bias Resistor Built-in Transistor)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTA023EMSOT-723Digital transistor (PNP, resistors built in), 3 pins, ROHMDigital transistor (PNP, resistors built in)SOT-7233 pinsROHM
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    ROHM
    Package
    SOT-723
    Pins
    3
    Details
    PNP -100mA -50V Digital Transistor (Bias Resistor Built-in Transistor)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTA023EUBSOT-323Digital transistor (PNP, resistors built in), 3 pins, ROHMDigital transistor (PNP, resistors built in)SOT-3233 pinsROHM
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    ROHM
    Package
    SOT-323
    Pins
    3
    Details
    PNP -100mA -50V Digital Transistor (Bias Resistor Built-in Transistor)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • EDZV16BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • EDZVFH16BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    SOD-523
    Pins
    2
    Details
    Zener Diode (AEC-Q101 qualified)
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GALI-55+SOT-89RF amplifier (MMIC), 3 pins, Mini-CircuitsRF amplifier (MMIC)SOT-893 pinsMini-Circuits
    What it is
    RF amplifier (MMIC)
    Maker
    Mini-Circuits
    Package
    SOT-89
    Pins
    3
    Details
    MMIC amplifier, DC-4 GHz
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, on the output pin that the bias resistor or choke feeds.

    Working, it reads

    The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

    Dead, it reads

    • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
    • Output pin at the full supply voltage: open inside, no current flowing.
    On the board:
    Measured on the board with power on; the bias network is part of the reading.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The figures depend on the part and its bias resistor. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LBZT52B16T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LBZX84B16LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LEDZ16BPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LEDZ16BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LUDZS16BT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MM5Z3V9-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
    What it is
    Zener diode
    Maker
    SeCoS
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MT5Z3V9-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
    What it is
    Zener diode
    Maker
    SeCoS
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PDTA114YUSOT-323Digital transistor (PNP, resistors built in), 3 pins, NexperiaDigital transistor (PNP, resistors built in)SOT-3233 pinsNexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-323
    Pins
    3
    Details
    PNP resistor-equipped transistor; R1 = 10 kΩ, R2 = 47 kΩ
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-LBZT52B16T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-LBZX84B16LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-LBZX84B16LT1G-SSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-LEDZ16BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-LUDZS16BT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode, VZ Min 15.85 V, VZ Nom 16.2 V, VZ Max 16.51 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SBZX584B3V9-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
    What it is
    Zener diode
    Maker
    SeCoS
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TBZX584B3V9SOD-523Zener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-5232 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-523
    Pins
    2
    Details
    3.9V, 150mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UDZ16BSOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UDZV16BSOD-323Zener diode, 2 pins, ROHMZener diodeSOD-3232 pinsROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UDZVFH16BSOD-323Zener diode, 2 pins, ROHMZener diodeSOD-3232 pinsROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    SOD-323
    Pins
    2
    Details
    Zener Diode (AEC-Q101 qualified)
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • VDZ16BSOD-723Zener diode, 2 pins, YFWZener diodeSOD-7232 pinsYFW
    What it is
    Zener diode
    Maker
    YFW
    Package
    SOD-723
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • EIA-96:550603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
    What it is
    Precision resistor (EIA-96 code)
    Maker
    Not recorded
    Package
    0603
    Pins
    2
    Details
    EIA-96 precision chip resistor, code 55 stands for 365 in the E96 table; the printed mark adds a multiplier letter (55A = 365 Ohm, 55B = 3.65 kOhm)
    Source
    Added by hand from a published table

    Is it dead?

    Ohms range, across it, power off.

    Working, it reads

    Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

    Dead, it reads

    • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
    • Well above its marked value: drifted high.
    • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
    On the board:
    A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
    Compare:
    The same position on another channel usually carries the same value, and so does the matching part on another board.
    Watch for:
    A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 74AUP1Z125GWSOT-3636 pins, NXPNot recordedSOT-3636 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-363
    Pins
    6
    Details
    CMOS logic IC: X-tal driver with enable and internal resistor
    Source
    Published code list

    Is it dead?

    Ohms range, across it, power off.

    Working, it reads

    Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

    Dead, it reads

    • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
    • Well above its marked value: drifted high.
    • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
    On the board:
    A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
    Compare:
    The same position on another channel usually carries the same value, and so does the matching part on another board.
    Watch for:
    A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AP8822N-25GASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 2.5V±2%, -Reset ODO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 14 more parts have no package on record
    • BBY57-02LInfineonNot recordedNot recordedNot recordedInfineon
      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX584B20Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX584B22Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ET551ADJY1BLDO regulator, ETEKLDO regulatorNot recordedNot recordedETEK
      What it is
      LDO regulator
      Maker
      ETEK
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • MMBT8550Transistor, Taitron ComponentsTransistorNot recordedNot recordedTaitron Components
      What it is
      Transistor
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SAV-551+RF amplifier (MMIC), Mini-CircuitsRF amplifier (MMIC)Not recordedNot recordedMini-Circuits
      What it is
      RF amplifier (MMIC)
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MMIC amplifier, 0.045-6 GHz
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, on the output pin that the bias resistor or choke feeds.

      Working, it reads

      The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

      Dead, it reads

      • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
      • Output pin at the full supply voltage: open inside, no current flowing.
      On the board:
      Measured on the board with power on; the bias network is part of the reading.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The figures depend on the part and its bias resistor. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM05CB1A4XXEI2G2 pins, SG MicroNot recordedNot recorded2 pinsSG Micro
      What it is
      Not recorded
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      2
      Details
      Low Capacitance 1-Channel ESD Protection
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM892B-1.6XUDH4GVoltage supervisor, 4 pins, SG MicroVoltage supervisorNot recorded4 pinsSG Micro
      What it is
      Voltage supervisor
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      Standard CMOS Voltage Detector ICs
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TAV1-551+RF amplifier (MMIC), Mini-CircuitsRF amplifier (MMIC)Not recordedNot recordedMini-Circuits
      What it is
      RF amplifier (MMIC)
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MMIC amplifier, 0.045-6 GHz
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, on the output pin that the bias resistor or choke feeds.

      Working, it reads

      The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

      Dead, it reads

      • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
      • Output pin at the full supply voltage: open inside, no current flowing.
      On the board:
      Measured on the board with power on; the bias network is part of the reading.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The figures depend on the part and its bias resistor. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 74AUP1Z125GFNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: X-tal driver with enable and internal resistor
      Source
      Published code list

      Is it dead?

      Ohms range, across it, power off.

      Working, it reads

      Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

      Dead, it reads

      • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
      • Well above its marked value: drifted high.
      • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
      On the board:
      A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
      Compare:
      The same position on another channel usually carries the same value, and so does the matching part on another board.
      Watch for:
      A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 74AUP1Z125GMNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: X-tal driver with enable and internal resistor
      Source
      Published code list

      Is it dead?

      Ohms range, across it, power off.

      Working, it reads

      Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

      Dead, it reads

      • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
      • Well above its marked value: drifted high.
      • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
      On the board:
      A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
      Compare:
      The same position on another channel usually carries the same value, and so does the matching part on another board.
      Watch for:
      A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 74AUP1Z125GNNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: X-tal driver with enable and internal resistor
      Source
      Published code list

      Is it dead?

      Ohms range, across it, power off.

      Working, it reads

      Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

      Dead, it reads

      • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
      • Well above its marked value: drifted high.
      • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
      On the board:
      A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
      Compare:
      The same position on another channel usually carries the same value, and so does the matching part on another board.
      Watch for:
      A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 74AUP1Z125GSNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: X-tal driver with enable and internal resistor
      Source
      Published code list

      Is it dead?

      Ohms range, across it, power off.

      Working, it reads

      Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

      Dead, it reads

      • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
      • Well above its marked value: drifted high.
      • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
      On the board:
      A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
      Compare:
      The same position on another channel usually carries the same value, and so does the matching part on another board.
      Watch for:
      A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8822N-25GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±2%, -Reset ODO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

55 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Download WhatSMD on the App Store