Skip to content

SMD code search: identify a part by its marking

4 parts are printed 6JS. 12 printed with a similar-looking code.

Not sure which one you have?

Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ELM991271BCSOT-23LDO regulator, 3 pins, ELM TechnologyLDO regulatorSOT-233 pinsELM Technology
    What it is
    LDO regulator
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 12.7V±2%, 300mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3 more parts have no package on record
    • G683L12SA31UVoltage supervisor, 6 pins, Global Mixed-mode TechnologyVoltage supervisorNot recorded6 pinsGlobal Mixed-mode Technology
      What it is
      Voltage supervisor
      Maker
      Global Mixed-mode Technology
      Package
      Not recorded
      Pins
      6
      Details
      Low Voltage Reset IC
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5127BCHZener diode, PanjitZener diodeNot recordedNot recordedPanjit
      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5127BCH-AUZener diode, PanjitZener diodeNot recordedNot recordedPanjit
      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

12 more parts are printed with a code easy to misread as 6JS

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • SGM6032-1.8YTDI6Gprinted GJ5DFNDC-DC converter, 6 pins, SG MicroDC-DC converterDFN6 pinsSG Micro

    Printed GJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    DC-DC converter
    Maker
    SG Micro
    Package
    DFN
    Pins
    6
    Details
    6MHz, 600mA Synchronous Buck Regulator
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SN74LVC1G18DCKprinted CJ5SOT-363Logic gate, 6 pins, Texas InstrumentsLogic gateSOT-3636 pinsTexas Instruments

    Printed CJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Logic gate
    Maker
    Texas Instruments
    Package
    SOT-363
    Pins
    6
    Details
    1-of-2 Noninverting Demultiplexer With 3-State Deselected Output
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SK543-5printed CJ5SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric

    Printed CJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    n-MOS-d: FM-Tun, VHF-B, 20V, 30mA, 200mW, Idss=5..12mA
    Source
    Published code list

    Is it dead?

    Diode range and ohms range, part lifted.

    Working, it reads

    Depends on what it is. The datasheet, or an identical part, says.

    Dead, it reads

    • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
    • Open between every pair of pins: failed open, or a part that reads open when working.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SK968-5printed GJ5SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric

    Printed GJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    FET n-type: FM, 20V, 20mA, 200mW, Idss=5..12mA, Up<2.5V
    Source
    Published code list

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BSS80Cprinted CJsSOT-233 pins, InfineonNot recordedSOT-233 pinsInfineon

    Printed CJs on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    Si-pnp: Sw, 60V, 800mA, 330mW, B=100..300, >200MHz
    Source
    Published code list

    Is it dead?

    Diode range and ohms range, part lifted.

    Working, it reads

    Depends on what it is. The datasheet, or an identical part, says.

    Dead, it reads

    • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
    • Open between every pair of pins: failed open, or a part that reads open when working.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CMHZ5250Bprinted CJ5SOD-123Zener diode, 2 pins, Central SemiconductorZener diodeSOD-1232 pinsCentral Semiconductor

    Printed CJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Central Semiconductor
    Package
    SOD-123
    Pins
    2
    Details
    zener 500mW 5% 20V
    Source
    Published code list

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ELM991051BCprinted 6J5SOT-23LDO regulator, 3 pins, ELM TechnologyLDO regulatorSOT-233 pinsELM Technology

    Printed 6J5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 10.5V±2%, 300mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SN74AUP1T87DCKprinted 6J5SOT-3535 pins, Texas InstrumentsNot recordedSOT-3535 pinsTexas Instruments

    Printed 6J5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Texas Instruments
    Package
    SOT-353
    Pins
    5
    Details
    CMOS logic IC: 2-input EXCLUSIVE-NOR gate
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UM1560S-45printed 6J5SOT-23-5LDO regulator, 5 pins, Union SemiconductorLDO regulatorSOT-23-55 pinsUnion Semiconductor

    Printed 6J5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Union Semiconductor
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 4.5V±2%, 200mA, +CE
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3 more parts have no package on record
    • PZS514V7BCHprinted CJSZener diode, PanjitZener diodeNot recordedNot recordedPanjit

      Printed CJS on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS514V7BCH-AUprinted CJSZener diode, PanjitZener diodeNot recordedNot recordedPanjit

      Printed CJS on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 2SK1067-5printed CJ5Sanyo ElectricNot recordedNot recordedNot recordedSanyo Electric

      Printed CJ5 on the part. Easy to misread as 6JS. Check that character with a loupe before you order anything.

      What it is
      Not recorded
      Maker
      Sanyo Electric
      Package
      Not recorded
      Pins
      Not recorded
      Details
      n-MOS-d: VHF/FM, 16V, 30mA, 150mW, Idss=5..12mA, Up<2,5V
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

11 more parts have codes that begin with 6JS

Codes that begin with 6JS

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • S6AF5.0Aprinted 6J5.0ASMAFTVS diode, 2 pins, SeCoSTVS diodeSMAF2 pinsSeCoS

    Printed 6J5.0A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    SeCoS
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S6AF51Aprinted 6J51ASMAFTVS diode, 2 pins, SeCoSTVS diodeSMAF2 pinsSeCoS

    Printed 6J51A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    SeCoS
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S6AF54Aprinted 6J54ASMAFTVS diode, 2 pins, SeCoSTVS diodeSMAF2 pinsSeCoS

    Printed 6J54A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    SeCoS
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S6AF58Aprinted 6J58ASMAFTVS diode, 2 pins, SeCoSTVS diodeSMAF2 pinsSeCoS

    Printed 6J58A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    SeCoS
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAW100printed CJSSSOT-1434 pins, Central SemiconductorNot recordedSOT-1434 pinsCentral Semiconductor

    Printed CJSS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Not recorded
    Maker
    Central Semiconductor
    Package
    SOT-143
    Pins
    4
    Details
    Si-diode: Dual, Sw, 75V, 250mA, Vf<1,25V (150mA), 6ns
    Source
    Published code list

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ51Aprinted CJ51ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ51A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ51CAprinted CJ51ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ51A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ54Aprinted CJ54ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ54A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ54CAprinted CJ54ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ54A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ58Aprinted CJ58ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ58A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMCJ58CAprinted CJ58ASMCTVS diode, 2 pins, SecosTVS diodeSMC2 pinsSecos

    Printed CJ58A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Secos
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Download WhatSMD on the App Store
  • Get WhatSMD on Google Play