  • 2SB766ASOT-89PNP transistor, 3 pins, SeCoSPNP transistorSOT-893 pinsSeCoS
    What it is
    PNP transistor
    Maker
    SeCoS
    Package
    SOT-89
    Pins
    3
    Details
    PNP bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AMP01EA045SOD-123FSchottky diode, 2 pins, ShindengenSchottky diodeSOD-123F2 pinsShindengen
    What it is
    Schottky diode
    Maker
    Shindengen
    Package
    SOD-123F
    Pins
    2
    Details
    Schottky Barrier Diodes 45V, 1A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AP5N2K2EN1SOT-723N-channel MOSFET, 3 pins, Advanced Power ElectronicsN-channel MOSFETSOT-7233 pinsAdvanced Power Electronics
    What it is
    N-channel MOSFET
    Maker
    Advanced Power Electronics
    Package
    SOT-723
    Pins
    3
    Details
    50 V, 0.2 A N-channel MOSFET
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • APL3537BWLCSPLoad switch, AnpecLoad switchWLCSPNot recordedAnpec
    What it is
    Load switch
    Maker
    Anpec
    Package
    WLCSP
    Pins
    Not recorded
    Details
    Ultra-Low On-Resistance, Power Load Switch With Soft Start
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground.

    Working, it reads

    Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

    Dead, it reads

    • Output at the input voltage while switched off: the pass element has shorted.
    • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
    On the board:
    An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ARB520S-30-HFSOD-523Schottky diode, 2 pins, ComchipSchottky diodeSOD-5232 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOD-523
    Pins
    2
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAS16-03WSOD-323Switching diode, 2 pins, InfineonSwitching diodeSOD-3232 pinsInfineon
    What it is
    Switching diode
    Maker
    Infineon
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAT54X-CSOD-523Schottky diode, 2 pins, SeCoSSchottky diodeSOD-5232 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BB555-02VSOD-5232 pins, InfineonNot recordedSOD-5232 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range and ohms range, part lifted.

    Working, it reads

    Depends on what it is. The datasheet, or an identical part, says.

    Dead, it reads

    • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
    • Open between every pair of pins: failed open, or a part that reads open when working.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CH520S-30AGPSOD-523Schottky diode, 2 pins, ChenmkoSchottky diodeSOD-5232 pinsChenmko
    What it is
    Schottky diode
    Maker
    Chenmko
    Package
    SOD-523
    Pins
    2
    Details
    SCHOTTKY BARRIER DIODE, 30 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CH520S-30GPSOD-523Schottky diode, 2 pins, ChenmkoSchottky diodeSOD-5232 pinsChenmko
    What it is
    Schottky diode
    Maker
    Chenmko
    Package
    SOD-523
    Pins
    2
    Details
    SCHOTTKY BARRIER DIODE, 30 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CH3904TGPSOT-416NPN transistor, 3 pins, ChenmkoNPN transistorSOT-4163 pinsChenmko
    What it is
    NPN transistor
    Maker
    Chenmko
    Package
    SOT-416
    Pins
    3
    Details
    NPN Switching Transistor, 40 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CHTN02DTGP-ASOT-416NPN transistor, 3 pins, ChenmkoNPN transistorSOT-4163 pinsChenmko
    What it is
    NPN transistor
    Maker
    Chenmko
    Package
    SOT-416
    Pins
    3
    Details
    NPN Switching Transistor, 40 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD5B5VL-2SOD-523TVS diode, 2 pins, WillsemiTVS diodeSOD-5232 pinsWillsemi
    What it is
    TVS diode
    Maker
    Willsemi
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD9D3V3CSOD-923ESD protection diode, 2 pins, LeiditechESD protection diodeSOD-9232 pinsLeiditech
    What it is
    ESD protection diode
    Maker
    Leiditech
    Package
    SOD-923
    Pins
    2
    Details
    ESD protection diode, VRWM 3.3 V, Cj 15 pF
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD9N5B-2SOD-882TVS diode, 2 pins, WillsemiTVS diodeSOD-8822 pinsWillsemi
    What it is
    TVS diode
    Maker
    Willsemi
    Package
    SOD-882
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD9N5BL-2SOD-882TVS diode, 2 pins, WillsemiTVS diodeSOD-8822 pinsWillsemi
    What it is
    TVS diode
    Maker
    Willsemi
    Package
    SOD-882
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD9X5.0SSOD-923ESD protection diode, 2 pins, onsemiESD protection diodeSOD-9232 pinsonsemi
    What it is
    ESD protection diode
    Maker
    onsemi
    Package
    SOD-923
    Pins
    2
    Details
    ESD Protection Diode Series, Series
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD56101D05-2DFN1610-2TVS diode, 2 pins, WillsemiTVS diodeDFN1610-22 pinsWillsemi
    What it is
    TVS diode
    Maker
    Willsemi
    Package
    DFN1610-2
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GBLC08ISOD-323ESD protection diode, 2 pins, ProTek DevicesESD protection diodeSOD-3232 pinsProTek Devices
    What it is
    ESD protection diode
    Maker
    ProTek Devices
    Package
    SOD-323
    Pins
    2
    Details
    Ultra Low Capacitance TVS Array
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GBLC08I-LF-T7SOD-3232 pins, UMWNot recordedSOD-3232 pinsUMW
    What it is
    Not recorded
    Maker
    UMW
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range and ohms range, part lifted.

    Working, it reads

    Depends on what it is. The datasheet, or an identical part, says.

    Dead, it reads

    • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
    • Open between every pair of pins: failed open, or a part that reads open when working.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GSFC0213SOT-23P-channel MOSFET, 3 pins, Good-ArkP-channel MOSFETSOT-233 pinsGood-Ark
    What it is
    P-channel MOSFET
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    P-channel MOSFET, 20 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GSRB520S-30SOD-523Schottky diode, 2 pins, Good-ArkSchottky diodeSOD-5232 pinsGood-Ark
    What it is
    Schottky diode
    Maker
    Good-Ark
    Package
    SOD-523
    Pins
    2
    Details
    Schottky diode, 30 V, 200 mA
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • IRLML2803SOT-23N-channel MOSFET, 3 pins, InfineonN-channel MOSFETSOT-233 pinsInfineon
    What it is
    N-channel MOSFET
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    30V Single N-Channel Power MOSFET in a Micro 3 package
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 27 more parts have no package on record
    • AON1606MOSFET, Alpha & Omega SemiconductorMOSFETNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Low-voltage (12-30 V) MOSFET
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board
      the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AON1606LMOSFET, Alpha & Omega SemiconductorMOSFETNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Low-voltage (12-30 V) MOSFET
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board
      the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ8S204BLS-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      ESD protection diode
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection for high-speed interfaces
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ8S204BLS-05ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      ESD protection diode
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection for high-speed interfaces
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ8S322UD2-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      ESD protection diode
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection for high-speed interfaces
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ8829ADI-05ESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
      What it is
      ESD protection diode
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection for high-speed interfaces
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • APL3233BBattery protection IC, AnpecBattery protection ICNot recordedNot recordedAnpec
      What it is
      Battery protection IC
      Maker
      Anpec
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Li+ Charger Protection IC
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • APW7582BDC-DC converter, AnpecDC-DC converterNot recordedNot recordedAnpec
      What it is
      DC-DC converter
      Maker
      Anpec
      Package
      Not recorded
      Pins
      Not recorded
      Details
      0.6A, 5V Input, Low IQ Buck Converter
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BAT15-098LRHSchottky diode, InfineonSchottky diodeNot recordedNot recordedInfineon
      What it is
      Schottky diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BGU8010RF amplifier (MMIC), 6 pins, NXPRF amplifier (MMIC)Not recorded6 pinsNXP
      What it is
      RF amplifier (MMIC)
      Maker
      NXP
      Package
      Not recorded
      Pins
      6
      Details
      SiGe:C Low Noise Amplifier MMIC for GPS, GLONASS, Galileo and Compass
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, on the output pin that the bias resistor or choke feeds.

      Working, it reads

      The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

      Dead, it reads

      • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
      • Output pin at the full supply voltage: open inside, no current flowing.
      On the board:
      Measured on the board with power on; the bias network is part of the reading.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The figures depend on the part and its bias resistor. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CH520G2-30GP-ASchottky diode, ChenmkoSchottky diodeNot recordedNot recordedChenmko
      What it is
      Schottky diode
      Maker
      Chenmko
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SCHOTTKY BARRIER DIODE, 30 V, 0.2 A
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CPDWZ3V3MSB-HFESD protection diode, ComchipESD protection diodeNot recordedNot recordedComchip
      What it is
      ESD protection diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      3.3 V bidirectional ESD protection diode
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESD5V0AE1ESD protection diode, JSCJESD protection diodeNot recordedNot recordedJSCJ
      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESD9B5VL-2TVS diode, WillsemiTVS diodeNot recordedNot recordedWillsemi
      What it is
      TVS diode
      Maker
      Willsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESD217-B1-02ELESD protection diode, InfineonESD protection diodeNot recordedNot recordedInfineon
      What it is
      ESD protection diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESD5484FCESD protection diode, onsemiESD protection diodeNot recordedNot recordedonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESD5661D07-2TVS diode, WillsemiTVS diodeNot recordedNot recordedWillsemi
      What it is
      TVS diode
      Maker
      Willsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDA6V1P6STMicroelectronicsNot recordedNot recordedNot recordedSTMicroelectronics
      What it is
      Not recorded
      Maker
      STMicroelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDA33CPESD protection diode, LeiditechESD protection diodeNot recordedNot recordedLeiditech
      What it is
      ESD protection diode
      Maker
      Leiditech
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 3.3 V, Cj 12 pF
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDM5V0AE1ESD protection diode, JSCJESD protection diodeNot recordedNot recordedJSCJ
      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSBD240Schottky diode, Good-ArkSchottky diodeNot recordedNot recordedGood-Ark
      What it is
      Schottky diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, 40 V, 2 A
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSEN3B0013ESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
      What it is
      ESD protection diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 3.3 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSEN5B001ESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
      What it is
      ESD protection diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSEN5B002ESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
      What it is
      ESD protection diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSEN5B0013ESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
      What it is
      ESD protection diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSESUC5VD0603-2BESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
      What it is
      ESD protection diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • GSRB520SD1Schottky diode, Good-ArkSchottky diodeNot recordedNot recordedGood-Ark
      What it is
      Schottky diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, 30 V, 200 mA
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

117 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Download WhatSMD on the App Store
  • Get WhatSMD on Google Play