SMD code search: identify a part by its marking

2 parts are printed C032. 1 printed with a similar-looking code.

2 parts are printed C032

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

all Ricoh. What differs:

  • R5323K026BDFNNot recordedDFNNot recorded
    What it is
    Not recorded
    Maker
    Ricoh
    Package
    DFN
    Pins
    Not recorded
    Details
    VR-IC: LDO, Dual out, sep. CE, Vo1=3.3V, Vo2=1.9V, 150mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • RP200Q322BSOT-23-5LDO regulator, 5 pinsLDO regulatorSOT-23-55 pins
    What it is
    LDO regulator
    Maker
    Ricoh
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 3.2V±1.0%, 300mA, +CE, AE(mode)
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

1 more part is printed with a code easy to misread as C032

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • R1154H032Bprinted G032SOT-89-55 pins, Nisshinbo Micro DevicesSOT-89-55 pinsNisshinbo Micro Devices

    Printed G032 on the part. Easy to misread as C032. Check that character with a loupe before you order anything.

    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-89-5
    Pins
    5
    Details
    VR-IC: LDO, CE, 3.2V±2%, 150mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

22 more parts have codes that begin with C032

Codes that begin with C032

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • AIC1748-32GU3printed GD32GSOT-23LDO regulator, 3 pins, Analog IntegrationsLDO regulatorSOT-233 pinsAnalog Integrations

    Printed GD32G. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    LDO regulator
    Maker
    Analog Integrations
    Package
    SOT-23
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 3.2V±2%, 600mA
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AIC1952-3ZGG6Tprinted GQ3ZGSOT-23-6LDO regulator, 6 pins, Analog IntegrationsLDO regulatorSOT-23-66 pinsAnalog Integrations

    Printed GQ3ZG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    LDO regulator
    Maker
    Analog Integrations
    Package
    SOT-23-6
    Pins
    6
    Details
    Linear voltage regulator IC: LDO, Dual out, Vout1/Vout2=2.85V/3.3V±2%, 300mA, +CE
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D320ERprinted 6D320USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D320. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.0V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D321ERprinted 6D321USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D321. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.1V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D322ERprinted 6D322USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D322. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.2V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D323ERprinted 6D323USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D323. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.3V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D324ERprinted 6D324USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D324. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.4V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D325ERprinted 6D325USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D325. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.5V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D326ERprinted 6D326USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D326. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.6V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D327ERprinted 6D327USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D327. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.7V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D328ERprinted 6D328USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D328. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.8V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6104D329ERprinted 6D329USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed 6D329. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.9V5%, Hst, ±Reset PPO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D320ERprinted CD320USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD320. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.0V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D321ERprinted CD321USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD321. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.1V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D322ERprinted CD322USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD322. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.2V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D323ERprinted CD323USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD323. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.3V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D324ERprinted CD324USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD324. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.4V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D325ERprinted CD325USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD325. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.5V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D326ERprinted CD326USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD326. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.6V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D327ERprinted CD327USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD327. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.7V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D328ERprinted CD328USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD328. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.8V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • XC6115D329ERprinted CD329USP-6CVoltage supervisor, 6 pins, TorexVoltage supervisorUSP-6C6 pinsTorex

    Printed CD329. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    USP-6C
    Pins
    6
    Details
    CMOS-IC: VDet 2.9V, +Rst PPO, -Rst ODO, Wt=100ms, Rt=100ms
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play
  • Coming soon to the App Store