SMD code search: identify a part by its marking
1 part is printed COC. 181 printed with a similar-looking code.
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
The only part printed COC in our tables
SGM41100A-425N09YUDT6G
- What it is
- Battery protection IC
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 6
- Details
- True Monolithic Li-Ion/Polymer Battery Protector in Tiny Thin Package
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Was it this one?
Printed with a code easy to misread
These parts are printed with a character that is easy to misread as what you typed. The odd one out is marked on each.
1.5SMBJ6.0Aprinted GDGSMBTVS diode, 2 pins, RectronTVS diodeSMB2 pinsRectron
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Rectron
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1.5SMBJ6.0AVprinted GDGSMBTVS diode, 2 pins, RectronTVS diodeSMB2 pinsRectron
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Rectron
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
824540600printed GDGSMCTVS diode, 2 pins, Würth ElektronikTVS diodeSMC2 pinsWürth Elektronik
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Würth Elektronik
- Package
- SMC
- Pins
- 2
- Details
- WE-TVSP Power TVS Diode SMCJ6.0A
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ASMCJ6.0A-HFprinted GDGSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMC
- Pins
- 2
- Details
- 6 V 1500 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATV15C6V0J-HFprinted GDGSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMC
- Pins
- 2
- Details
- 6 V 1500 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC868-25printed CDCSOT-89NPN transistor, 3 pins, NexperiaNPN transistorSOT-893 pinsNexperia
Printed CDC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- NPN transistor
- Maker
- Nexperia
- Package
- SOT-89
- Pins
- 3
- Details
- 20 V, 2 A NPN medium-power transistor, gain group 25
- Source
- Manufacturer datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
EG01Cprinted G0CAxialRectifier, 2 pins, SankenRectifierAxial2 pinsSanken
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Rectifier
- Maker
- Sanken
- Package
- Axial
- Pins
- 2
- Details
- Fast Recovery Diode (VRM = 1000 V, IF(AV) = 0.5 A, trr = 100 ns)
- Source
- Manufacturer datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESDCAN06-2BWYprinted C06SOT-323TVS diode, 3 pins, STMicroelectronicsTVS diodeSOT-3233 pinsSTMicroelectronics
Printed C06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- STMicroelectronics
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ET5H560Cprinted 60CSOT-89-5LDO regulator, 5 pins, ETEKLDO regulatorSOT-89-55 pinsETEK
Printed 60C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- ETEK
- Package
- SOT-89-5
- Pins
- 5
- Source
- Manufacturer datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
FDC606Pprinted 606SOT-23-6P-channel MOSFET, 6 pins, onsemiP-channel MOSFETSOT-23-66 pinsonsemi
Printed 606 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- P-channel MOSFET
- Maker
- onsemi
- Package
- SOT-23-6
- Pins
- 6
- Details
- MOSFET - P-Channel, POWERTRENCH
- Source
- Manufacturer datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
GSMA6T58CAprinted 6DGSMATVS diode, 2 pins, Good-ArkTVS diodeSMA2 pinsGood-Ark
Printed 6DG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Good-Ark
- Package
- SMA
- Pins
- 2
- Details
- TVS diode, 600 W
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MMSZ5253Eprinted CD6SOD-123Zener diode, 2 pins, onsemiZener diodeSOD-1232 pinsonsemi
Printed CD6 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-123
- Pins
- 2
- Details
- Zener Voltage Regulators MMSZ52xxET1G Series, SZMMSZ52xxET1G Series
- Source
- Manufacturer datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NCP711ASN300printed GDCSOT-23-5LDO regulator, 5 pins, onsemiLDO regulatorSOT-23-55 pinsonsemi
Printed GDC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- SOT-23-5
- Pins
- 5
- Details
- LDO Regulator, 100 mA, 18 V, 1 mA IQ, with PG
- Source
- Manufacturer datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PAM31DOAB6.0Aprinted GDGSMCTVS diode, 2 pins, ProTek DevicesTVS diodeSMC2 pinsProTek Devices
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMC
- Pins
- 2
- Details
- 1500 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PJC7406printed C06SOT-323MOSFET, 3 pins, PanjitMOSFETSOT-3233 pinsPanjit
Printed C06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- MOSFET
- Maker
- Panjit
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PJSOT24C-03printed 6DCSOT-23ESD protection diode, 3 pins, PanjitESD protection diodeSOT-233 pinsPanjit
Printed 6DC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM818B-2.7LXN3Gprinted GQ6SOT-23Voltage supervisor, 3 pins, SG MicroVoltage supervisorSOT-233 pinsSG Micro
Printed GQ6 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Voltage supervisor
- Maker
- SG Micro
- Package
- SOT-23
- Pins
- 3
- Details
- 2.7 V threshold, Micro-Power Voltage Detector
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM818B-3.0LXN3Gprinted GQCSOT-23Voltage supervisor, 3 pins, SG MicroVoltage supervisorSOT-233 pinsSG Micro
Printed GQC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Voltage supervisor
- Maker
- SG Micro
- Package
- SOT-23
- Pins
- 3
- Details
- 3 V threshold, Micro-Power Voltage Detector
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM890B-1.1XN5Gprinted G0GSOT-23-5Voltage supervisor, 5 pins, SG MicroVoltage supervisorSOT-23-55 pinsSG Micro
Printed G0G on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Voltage supervisor
- Maker
- SG Micro
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage Detector with Separated Sense Pin and Delay Capacitor Pin
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM2580DYN5Gprinted G0CSOT-23-5Load switch, 5 pins, SG MicroLoad switchSOT-23-55 pinsSG Micro
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Load switch
- Maker
- SG Micro
- Package
- SOT-23-5
- Pins
- 5
- Details
- Power Distribution Switch
- Source
- Manufacturer datasheet
Is it dead?
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM6022-4XTDI6Gprinted GDCDFNDC-DC converter, 6 pins, SG MicroDC-DC converterDFN6 pinsSG Micro
Printed GDC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- DC-DC converter
- Maker
- SG Micro
- Package
- DFN
- Pins
- 6
- Details
- 6MHz, 600mA Synchronous Buck Regulator
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SM4F6.0CAprinted 6.0CSOD-123FTVS diode, 2 pins, YFWTVS diodeSOD-123F2 pinsYFW
Printed 6.0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- YFW
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SM4F60CAprinted 60CSOD-123FTVS diode, 2 pins, YFWTVS diodeSOD-123F2 pinsYFW
Printed 60C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- YFW
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMAF6J350Aprinted 6QGSMAFTVS diode, 2 pins, YFWTVS diodeSMAF2 pinsYFW
Printed 6QG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMAF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMCG6.0Aprinted GDGSMCGTVS diode, 2 pins, VishayTVS diodeSMCG2 pinsVishay
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SMCG
- Pins
- 2
- Details
- 1500 W TVS diode, unidirectional
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMCJ6.0Aprinted GDGSMCTVS diode, 2 pins, SOCAYTVS diodeSMC2 pinsSOCAY
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- SOCAY
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMCJ6.0A-HFprinted GDGSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMC
- Pins
- 2
- Details
- 6 V 1500 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMCJ6.0A-Sprinted GDGSMCTVS diode, 2 pins, ProTek DevicesTVS diodeSMC2 pinsProTek Devices
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMC
- Pins
- 2
- Details
- 600 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMCJ6.0CAprinted GDGSMCTVS diode, 2 pins, Taitron ComponentsTVS diodeSMC2 pinsTaitron Components
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Taitron Components
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMF58CAprinted CDGSOD-123FTVS diode, 2 pins, Blue RocketTVS diodeSOD-123F2 pinsBlue Rocket
Printed CDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Blue Rocket
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMF60CAprinted 60CSOD-123FTVS diode, 2 pins, JieJieTVS diodeSOD-123F2 pinsJieJie
Printed 60C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TV15C6V0J-HFprinted GDGSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMC
- Pins
- 2
- Details
- 6 V 1500 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1.5SMCJ6.0Aprinted GDGSMCTVS diode, 2 pins, PanjitTVS diodeSMC2 pinsPanjit
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Panjit
- Package
- SMC
- Pins
- 2
- Details
- TVS: 6V, 145.6A, 1500W (1ms)
- Source
- Published code list
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1SMC6.0Aprinted GDGSMCTVS diode, 2 pins, onsemiTVS diodeSMC2 pinsonsemi
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- onsemi
- Package
- SMC
- Pins
- 2
- Details
- TVS: 6V, 145.6A, 1500W(1ms)
- Source
- Published code list
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
15SMBJ6.0Aprinted GDGSMBTVS diode, 2 pins, UN SemiconductorTVS diodeSMB2 pinsUN Semiconductor
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- UN Semiconductor
- Package
- SMB
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=6.0V, Vbr=6.67..7.37V, Ipp=145.6A, 1500W(1ms)
- Source
- Published code list
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AD7453ART-REEL7printed C0CSOT-23-88 pins, Analog DevicesNot recordedSOT-23-88 pinsAnalog Devices
Printed C0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23-8
- Pins
- 8
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AD7940BRJZ-REEL7printed C06SOT-23-66 pins, Analog DevicesNot recordedSOT-23-66 pinsAnalog Devices
Printed C06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23-6
- Pins
- 6
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AD7940BRMZ-REEL7printed C06MSOP-88 pins, Analog DevicesNot recordedMSOP-88 pinsAnalog Devices
Printed C06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- MSOP-8
- Pins
- 8
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ADCMP600BKSZ-R2printed G0CSOT-3535 pins, Analog DevicesNot recordedSOT-3535 pinsAnalog Devices
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-353
- Pins
- 5
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ADCMP600BRJZ-R2printed G0CSOT-23-55 pins, Analog DevicesNot recordedSOT-23-55 pinsAnalog Devices
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23-5
- Pins
- 5
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
9 more parts have no package on record
15BJ6.0Aprinted GDGTVS diode, JieJieTVS diodeNot recordedNot recordedJieJie
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- JieJie
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM3743YGprinted G06LED driver, 9 pins, SG MicroLED driverNot recorded9 pinsSG Micro
Printed G06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- LED driver
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 9
- Details
- 2-Channel White LED Driver for Smart Phone
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SGM41100A-425M03YUDT6Gprinted CO6Battery protection IC, 6 pins, SG MicroBattery protection ICNot recorded6 pinsSG Micro
Printed CO6 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Battery protection IC
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 6
- Details
- True Monolithic Li-Ion/Polymer Battery Protector in Tiny Thin Package
- Source
- Manufacturer datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SM6NT58CAprinted 6DGTVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
Printed 6DG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1SMC6.0AT3printed GDGTVS diode, onsemiTVS diodeNot recordedNot recordedonsemi
Printed GDG on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vbr=6.67..7.37V, Vrwm=6.0V, 145.6A, 1500W(1ms)
- Source
- Published code list
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2SC4673-Cprinted CDCSanyo ElectricNot recordedNot recordedNot recordedSanyo Electric
Printed CDC on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-npn: UHF, LN, 20V, 100mA, 400mW, B=40..80, 4.5GHz
- Source
- Published code list
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
74AHCT1G06GVprinted C06NXPNot recordedNot recordedNot recordedNXP
Printed C06 on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Inverter (ODO)
- Source
- Published code list
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ADCMP600BKJZprinted G0CComparator, Analog DevicesComparatorNot recordedNot recordedAnalog Devices
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Comparator
- Maker
- Analog Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rail-to-Rail comparator
- Source
- Published code list
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ADCMP600BRJZprinted G0CComparator, Analog DevicesComparatorNot recordedNot recordedAnalog Devices
Printed G0C on the part. Easy to misread as COC. Check that character with a loupe before you order anything.
- What it is
- Comparator
- Maker
- Analog Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rail-to-Rail comparator
- Source
- Published code list
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
132 more parts are not listed here. Type more of the code to narrow the list.
Did you find your part?
Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans
One code, several parts
Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.
- NPN transistor
- Varicap
- N-channel JFET
- Digital transistor ×2
- 3.6 V voltage detector
When more than one is left
Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.
When you cannot read it
Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.
Get the app
The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.
