SMD code 36C
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
36C on a chip resistor
23.2 kΩ
23.2 kΩ resistor, 1%
EIA-96 precision code: 36 stands for 232 in the E96 table, and the letter C is the multiplier, × 100. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 23.2 kΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 23.2 kΩ on the board is a fault. Open, or well above 23.2 kΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 23.2 kΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SMC, USP-6B, USP-6C), 36C is a part code instead. Those parts are listed below.
67 parts are printed 36C
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
P6SMB36CASMBTVS diode, 2 pins, DOWOTVS diodeSMB2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMB36CA(MS)SMBTVS diode, 2 pins, MSKSEMITVS diodeSMB2 pinsMSKSEMI
- What it is
- TVS diode
- Maker
- MSKSEMI
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMBF36CSMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMBF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P15SMCJ36CASMCFTVS diode, 2 pins, Formosa MicrosemiTVS diodeSMCF2 pinsFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- SMCF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM4SMA36CASMATVS diode, 2 pins, ProTek DevicesTVS diodeSMA2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMA
- Pins
- 2
- Details
- 400 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM10ST2336CSOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- 500 Watt TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM30DOAA36CASMBTVS diode, 2 pins, ProTek DevicesTVS diodeSMB2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMB
- Pins
- 2
- Details
- 600 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PSOT36CSOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- 500W TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PSOT36C-LF-T7SOT-233 pins, UMWNot recordedSOT-233 pinsUMW
- What it is
- Not recorded
- Maker
- UMW
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
S-LRCANL36T1GSOT-323ESD protection diode, 3 pins, LRCESD protection diodeSOT-3233 pinsLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- SOT-323
- Pins
- 3
- Details
- ESD protection diode, VRWM 36 V, IR @VRWM 0.1 μA, VBR Min 38 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SM4F36CASOD-123FTVS diode, 2 pins, YFWTVS diodeSOD-123F2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SM36SOT-23ESD protection diode, 3 pins, LeiditechESD protection diodeSOT-233 pinsLeiditech
- What it is
- ESD protection diode
- Maker
- Leiditech
- Package
- SOT-23
- Pins
- 3
- Details
- 36V, 300W, Surface Mount TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SM36CSOT-23TVS diode, 3 pins, UMWTVS diodeSOT-233 pinsUMW
- What it is
- TVS diode
- Maker
- UMW
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
2 more parts have no package on record
PLZ36CZener diode, VishayZener diodeNot recordedNot recordedVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 36 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SM15KWE36CATVS diode, ProTek DevicesTVS diodeNot recordedNot recordedProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 15 Kilowatt TVS Components
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.